Operating instructions – Harbor Freight Tools 65309 User Manual

Page 10

Advertising
background image

SKU 65309

For technical questions, please call 1-800-444-3353.

Page 10

OPeRaTinG inSTRucTiOnS

Read the enTiRe iMPORTanT

SaFeTY inFORMaTiOn

section at the beginning of this

manual including all text under

subheadings therein before set

up or use of this product.

inspect Generator and

equipment looking for

damaged, loose, and missing

parts before set up and starting.

if any problems are found, do

not use equipment until fixed

properly.

Start Procedure

before starting the engine:

Follow the Set up instruc-

a.

tions to prepare the equip-

ment. Follow all instructions

in the separate tractor man-

ual.

inspect the generator and

b.

tractor.

Fill the tractor engine with

c.

the proper amount and type

of fuel and oil.

Set the tractor on a flat surface. Set

1.

the brake on the tractor. Ensure that

it is not in gear, and cannot move dur-

ing operation.
Unplug all loads from the Generator

2.

before starting to prevent permanent

damage to connected devices.
Start and operate the tractor accord-

3.

ing to the provided engine manual.
Engage the tractor PTO drive.

4.

Set the tractor’s PTO speed to 540

5.

RPM.

Test each GFCI outlet by pressing the

6.

TEST button. The green light on that

outlet should go out. Then press the

RESET button. The green light on

that outlet should come back on. If

either GFCI outlet does not function

as described have a qualified electri-

cian repair the generator before use.
With the devices turned OFF, plug the

7.

devices into the appropriate outlets.

cauTiOn! Do not plug in or unplug

electrical loads while the loads are

turned on.
Turn on the devices one at a time

8.

from the largest to the smallest.

Check the frequency meter reading

on the Control Panel. If the reading

has dropped below 60 Hz, do not

connect any additional loads.
Be sure that all devices are in good

9.

working order before connecting

them to the generator. If a device

begins to operate abnormally, be-

comes sluggish, or stops suddenly,

turn off the device. Then disconnect

the device and examine it for signs of

malfunction.

note: If an overloaded circuit causes the

AC circuit breaker to switch off, re-

duce the electrical load on the circuit

and wait a few minutes before reset-

ting the circuit breaker.
The DC terminal may be used operat-

10.

ing 12 VDC portable devices only.

WaRninG: Do not use this generator

to charge 12 VDC batteries without a

charge controller. Directly charging a

12 Volt battery may cause the battery

to overheat and possibly explode.