Harbor Freight Tools 65309 User Manual

Page 11

Advertising
background image

SKU 65309

For technical questions, please call 1-800-444-3353.

Page 11

cauTiOn: Do not attempt to start an auto-

mobile engine with this generator.

Voltage feedback from the running

automobile may damage the genera-

tor.

note: The DC terminal may be used while

the AC power is in use. An overload-

ed DC circuit will trip the DC circuit

protector (push button comes out).

If this happens, wait a few minutes

before pushing in the circuit protector

to resume operation.
Watch the Volt Meter to determine

11.

the current load on the generator.

If the Volt Meter reading falls below

110 V~ (or the voltage requirement

of attached devices), remove some

devices from the system to reduce

demand on the generator.

WaRninG! TO PRevenT SeRiOuS

injuRY FROM eLecTRic ShOcK:

use the GFci unit properly.

If the power supply to either duplex

outlet is interrupted, there may be a

short in the attached device’s wiring

that is tripping the GFCI unit. Check

all wiring connections carefully for

moisture and damaged insulation

before pressing the reset button.

if the GFci unit trips again

immediately or after a short while,

discontinue use immediately and

have the generator and the device

attached to that outlet serviced by

a qualified electrician.

Stopping the Generator

Turn OFF all attached devices.

1.

Unplug the cords from the Generator.

2.

Turn OFF the tractor engine.

3.

Advertising