Specifications, Ordering information – Honeywell C645A-E User Manual

Page 2

Advertising
background image

60-2159—8

2

C645A-E PRESSURE SWITCHES

SPECIFICATIONS

Models:

C645A,C,D Pressure Switches—break a circuit when

pressure falls to scale setting minus the differential.
Refer to Table 1.

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the
TRADELINE® catalog or price sheets for complete ordering number, or specify—

1. Order number.

3. Optional specifications.

2. Air or gas control on C645A,B models.

4. Accessories, if desired.

If you have additional questions, need further information, or would like to comment on our products or services please write or phone:

1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory).
2. Honeywell Home and Building Control Customer Relations

Honeywell, 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International sales and
service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico,
Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

C645B Pressure Switches—break a circuit when pressure

rises to scale setting. Refer to Table 1.

C645E—breaks circuit when pressure falls to scale setting

minus the differential. Refer to Table 1.

Table 1. Pressure switch model selection.

a

Locks out when pressure falls to setpoint minus differential; can be reset manually after pressure rises to setpoint.

b

Locks out when pressure rises to setpoint; can be manually reset after pressure falls to setpoint minus differential.

c

Without indicator on Auto Recycle; with indicator on Lockout model.

d

With surge orifice.

Switch Ratings (Amperes):

Model

120 Vac

240 Vac

C645A

Full Load

7.4

3.7

C645B

Locked Rotor

44.4

22.2

C645D

C645C

Full Load

8.0

5.1

Locked Rotor

48.0

30.6

C645E

Full Load

7.4

3.7

Locked Rotor

44.4

22.2

All models also rated 2A at 30 Vac.

Alternate Electrical Ratings when used with Honeywell
Flame Safeguard Programmers (all C645 models):

Ignition
Transformer

540 VA

Pilot Valve

50

Main Valve

250 VA with 10 times inrush.
400 VA with 2-1/2 times inrush.

Scale

Range

Scale

Range

Natural

or LP

Switching

Switch

Position

Differential

Range

(in. wc)

Differential

Range

(kPa)

Maximum

Surge

Pressure

Maximum

Surge

Pressure

Cover

Models

(in. wc)

(kPa)

Gas

Air

Action

Indicator Nom.

Max. Nom.

Max.

(psi)

(kPa)

Window

C645A

3 to 21

0.7 to
5.2

Yes

Yes

Auto Recycle
or Lockout

a

Optional

1

3

0.2

0.7

5

34.5

Optional

5 to 35

1.2 to
8.7

Yes

Yes

c

1

4

0.2

1.0

5

34.5

Yes

C645B

3 to 21

0.7 to
5.2

Yes

Yes

Lockout

b

Yes

1

3

0.2

0.7

5

34.5

Optional

5 to 35

1.2 to
8.7

Yes

Yes

Yes

1

4

0.2

1.0

5

34.5

Yes

C645C

0.6 to
5.3

0.1 to
1.3

No

Yes Auto Recycle

or Lockout

a

Optional

0.2

0.8

0.05

0.02

1.5

10.3

No

2 to 20

d

0.5 to 5

No

Yes

Auto Recycle No

1

3

0.2

0.7

5

34.5

No

C645D

3 to 21

0.7 to
5.2

No

Yes Auto Recycle No

1

3

0.2

0.7

5

34.5

No

C645E

3 to 21

0.7 to
5.2

No

Yes Auto Recycle No

1

3

0.2

0.7

5

34.5

No

Advertising