SERVICING YOUR GENERATOR

SEDIMENT CUP CLEANING

SEDIMENT CUP

O-RING

FUEL VALVE LEVER

OFF

KEY

O

O

N

N

Turn the fuel valve lever to the OFF position and remove the key.
Open the left maintenance cover by turning its latch
counterclockwise.

Unscrew the sediment cup and remove it.
Remove the O-ring.

Close the left maintenance cover.

Reinstall the O-ring and sediment cup.

Wash the sediment cup and O-ring in nonflammable solvent, and
dry them thoroughly.

Stop the engine and keep heat,
sparks, and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.

Gasoline is highly flammable and
explosive.

You can be burned or seriously
injured when handling fuel.

2.

3.
4.

1.

5.

6.
7.

06/09/12 12:25:14 31Z25600_052