Batteries, Fig. 6—thermostat mounting, Fig. 7—insert timer batteries – Honeywell Y8196A User Manual

Page 4: Fig. 8—set timer, Fig. 9—attach cover

Advertising
background image

69-0637—2

4

TAB (2)

MOUNTING SLOT (2)

CAPTIVE
MOUNTING SCREWS

THERMOSTAT
BASE

WALLPLATE
OR SUBBASE

35

30

25

20

10

12

11

10

9

8

7

6

5

4

3 2

1 12

11

10

9

8

7

6

M8674

MOUNT THE THERMOSTAT

Note the tabs on the top inside edge of the thermostat

base. These tabs fit the slots molded into the top of the
subbase.

Hang thermostat base on subbase.
Insert the two captive mounting screws located in the

bottom corners of the base (Fig. 6).

Firmly tighten the screws.

Fig. 6—Thermostat mounting.

INSERT TIMER BATTERIES

Power is supplied to the timer by two AAA alkaline

batteries (not included).

Install the batteries in the thermostat (Fig. 7).
Once a year or when batteries are dead, replace with two

new AAA alkaline batteries. We recommend Energizer

®

batteries.

Fig. 7—Insert timer batteries.

BATTERY LOCATION FOR
(2) AAA BATTERIES;
INSTALL WITH POSITIVE
ENDS UP

M8585

SET TIMER

Adjust the timer by moving the knob clockwise .

Do NOT reverse the knob.

When time is correctly set, the time indicator arrow

(Fig. 8) must point to the corresponding daytime (light) or
nighttime (dark) portion of the program dial.

Fig. 8—Set timer.

TIMER
SETTING
KNOB

TIME
INDICATOR
ARROW

M5161

PROGRAM
PINS (4)
SEE OWNER'S
MANUAL FOR
DETAILS

ATTACH THERMOSTAT COVER

Make sure the packing inserts in the thermostat base are

removed.

Place the two tabs on the upper edge of the cover into the

mounting slots in the thermostat base (Fig. 9).

Swing the cover downward until it catches at the bottom

of the base.

Fig. 9—Attach cover.

SET TEMPERATURE CONTROL LEVERS

The two levers on top of thermostat control the low and

high temperatures for energy savings and comfort control
(Fig. 10). The lever on the left (blue mark) controls the
lower temperature. The lever on the right (red mark) con-
trols the higher temperature.

We recommend pushing the levers together at an appro-

priate temperature for either heat or cool until the occupant
programs the thermostat and makes the final temperature
selections.

50 60

70 80

M8604