6

Fig. 11—Typical hookup for Y8196A Package (T8196A Thermostat/Q682A Subbase) in heating/cooling
system.

HEAT

OFF

COOL

ON

AUTO

H

C

FAN
SWITCH

THERMOSTAT

BATTERIES

SUBBASE

M2386A

HEAT
ANTICIPATOR

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

REMOTE INDICATION FOR FILTER OPTIONAL.

JUMPER W TO Y FOR HEAT PUMP COMPRESSOR CONTROL.

1

COOL
ANTICIPATOR

HEAT
ANTICIPATOR

SYSTEM
SWITCH

HEAT

OFF

COOL

O

G

Y

W

B

R

REVERSING
VALVE/

COOLING
DAMPER

REVERSING
VALVE/

HEATING
DAMPER

FAN
RELAY

HEAT
RELAY

COMPRESSOR
CONTACTOR

1

L2

L1

(HOT)

2

2

TIMER

3

3

FALL

H

C

FALL

FILTER
LIGHT

SWITCH