REPLACING FAN MOTORS

Turn power off and allow cooling fans to run until the control box is cooled off.

DISCONNECT UNIT FROM POWER SUPPLY OR TURN POWER OFF AT WALL BREAKER.

NOTE: PERFORM THIS MAINTENANCE ONLY WHEN THE
CONVEYOR SANDWICH WARMER IS COMPLETELY COOL.

1. Remove the panel with the fan that needs replaced.

2. Unplug the power supply cord. Remove any wire ties holding the cord to the fan. Disconnect the

ground wire if present.

3. Remove the four screws attaching the fan and grill to the panel.

4. Place the new fan on the panel in the same orientation and re-attach using the grill and screws.

5. Reconnect the power cord to the fan and secure it to the fan with wire ties in the original location.

6. Replace the air intake panel and turn on the machine.

7.

Check that both fans come on after the oven has heated up.