Holman qt14 User Manual

Page 8

Advertising
background image

IF FURTHER ASSISTANCE IS REQUIRED:
CONTACT STAR/HOLMAN FACTORY SERVICE TEAM AT 1-800-807-9054

6

#

CONVEYOR WILL NOT TURN, UNIT HEATS PROPERLY

o

DISCONNECT UNIT FROM POWER SOURCE

o

Check both fuses (replace if necessary)

o

Check for obstructions that may have caused a conveyor jam. Utensils, foil or

large pieces of food could stall the motor. If there are no visible obstructions, try
turning the belt manually. If the belt turns, remove the power supply panel and
check for loose sprockets or chain. Realign any loose sprockets and re-tighten
the setscrews making sure the setscrews seat on the flats of the motor and drive
shafts.






o

If further assistance is required, contact the Star/Holman Factory Service

Team at 1-800-807-9054 (24 hours/day 7days a week).

#

COOLING FANS DO NOT START (fans should start after the machine is warmed up)

o

DISCONNECT UNIT FROM POWER SOURCE

o

Remove panels with fan motors and check fan blades for obstructions/breakage.

o

Check motor cords for secure connection

o

Call the Star/Holman Factory Service Team, as the fan switches and/or fan

motor(s) may need to be replaced.

Twin Fuse Block

Driven Sprocket

Drive Chain

Driver Sprocket

Advertising