SETTINGS

Using Thermostat Keys

The thermostat keys are used to:

set current day and time,

program times and setpoints for heating and cooling,

temporarily override program temperatures,

display present setting,

configure Installer Setup,

check System Test,

display outdoor temperature (select models),

set the system operation,

set the fan operation.

See Fig. 6 for the location of the keys.

System and Fan Settings

The system default setting is Heat and the fan default setting
is Auto. Use the System and Fan keys or switches to change
the settings. See Fig. 7. The fan settings can be set for each
program period individually. The system selection is for all the
program periods.

System settings control the thermostat operation as follows:

Heat: The thermostat controls the heating.
Off: Both the heating and cooling are off.
Cool: The thermostat controls the cooling.
Auto: The thermostat automatically changes between

heating and cooling operation, depending on the indoor
temperature.

Fan settings control the system fan as follows:

On: Fan operates continuously.
Auto: Fan operates with equipment.

Fig. 7. T8624D System and Fan key locations.

Fig. 6. T8624D key locations and descriptions.

M15042

Hold Temp

Run

Program

Copy

Daylight

Time

Set Current

Day/Time

System

Fan

Time

Set Program

Day

System

Fan

Wake

Leave

Return

Sleep

Heat/Cool

Settings

M10405A

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

INCREASE TEMPERATURE
SETTING OR SCROLL
FORWARD THROUGH
INSTALLER SETUP OPTIONS

DECREASE TEMPERATURE
SETTING OR SCROLL
BACKWARD THROUGH
INSTALLER SETUP OPTIONS

DISPLAY INFORMATION
SUCH AS PRESENT
SETTINGS AND OUTDOOR
TEMPERATURE

RETURN TO
NORMAL
OPERATIONS

ENTER
INDEFINITE
OR TIMED
HOLD MODE

SET CURRENT
DAY AND TIME

SET CURRENT OR
PROGRAM DAY

CHANGE BETWEEN
DAYLIGHT SAVINGS
AND STANDARD TIME

INCREASE TIME SETTING
OR SCROLL FORWARD
THROUGH INSTALLER SETUP
AND SYSTEM TEST

DECREASE TIME SETTING OR SCROLL
BACKWARD THROUGH INSTALLER
SETUP AND SYSTEM TEST

COPY ONE PROGRAMMED
DAY TO ANOTHER DAY

SET WAKE TIMES
AND SETPOINTS

CHANGE BETWEEN HEATING
AND COOLING SETPOINTS

SET LEAVE TIMES
AND SETPOINTS

SET RETURN TIMES
AND SETPOINTS

SET SLEEP
TIMES AND
SETPOINTS

SELECT SYSTEM
OPERATION

SELECT FAN
OPERATION

Advertising