Existing Chime

Chime Extender

Transmit Light

Figure 4

1 2 3 4 5 6 7 8

Figure 2

2. Open chime extender case. Press on cover with your

thumb and slide cover off as shown in Figure 2.

3. Install 4 “AAA” alkaline batteries (not included).

See diagram inside chime extender for correct battery
orientation.

Installation

Note: The chime extender can be oriented horizontally
or vertically.
1. Test range. Temporarily position chime extender

next to existing chime. Press “Test” button inside
chime extender to verify chime and chime extender
work properly. If chime does not sound, see Trouble-
shooting
.

2. Test function. With the chime extender still in the

intended location, activate the existing door chime.
If chime does not sound, try one or more of the fol-
lowing steps.
• Turn the microphone sensitivity adjustment knob

clockwise to increase microphone sensitivity (see
Figure 3).

• Temporarily reposition chime extender around

existing chime.

Test

Button

Microphone

Sensitivity

Adjustment

Microphone

Wire Terminals

Figure 3

Removable

Microphone

Wire

Routing

Slot