Warning, Installation: full vertical, Installation: alcove – Hearth and Home Technologies 21M-ACC User Manual

Page 10

Advertising
background image

Page 10

7039-131F

September 1, 2008

R

2100 Millennium Wood Stove (ACC)

B. Clearances to Combustibles (UL and ULC)

BACKWALL / SIDEWALL

A

B

C

D

E

F

E

F

CORNER INSTALLATION

STOVE TO CEILING

CLEARANCE

C

D

ALCOVE TOP VIEW

G

A

B

ALCOVE SIDE VIEW

NOTE: Clearances may only be reduced by means

approved by the regulatory authority having jurisdiction

Fire Risk.
• Comply with all minimum clearances to

combustibles as specified.

• Failure to comply may cause house fire.

WARNING

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.

A

B

C

D

E

F

G

H

INSTALLATION: Full Vertical

SINGLE WALL PIPE

15 (81) 11 (279) 21.5 (546) 1 (0) 8.5 (216) 17(42) 56 (1422)

N/A

DOUBLE WALL PIPE 8.75(222) 5.75 (146) 20 (508) 10.5 (267) 7.5 (191) 16 (406) 4 (1092)

N/A

INSTALLATION: Horizontal with Minimum 2 Foot Vertical Off Stove Top

SINGLE WALL PIPE

14 (56) 10 (254) 20.5 (521) 12 (05) 8.5 (216) 17 (42) 56 (1422)

9.5 (241)


DOUBLE WALL PIPE 9.5 (241) 5.5 (140) 21.5 (546) 1 (0) 7.5 (191) 16 (406) 4 (1092)

5 (127)

INSTALLATION: ALCOVE

Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL

10 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark

arrestor). Maximum depth of alcove shall be no more than 48"(1220mm) with a minimum height of 4" (1092mm) to top

of unit, and the referenced clearances.

DOUBLE WALL PIPE 9.5 (241) 5.5 (140) 21.5 (546) 1 (0)

N/A

N/A

4 (1092)

5 (127)

NOTE: Service Space

In order to replace the tube channel assembly a clearance

of 17 inches (42mm) is required on the right side of stove

in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-

nected from the chimney to proceed with the tube replace-

ment.