2100 Millennium Wood Stove (ACC)

Hearth & Home Technologies welcomes you to our tradi-

tion of excellence! In choosing a Quadra-Fire appliance,

you have our assurance of commitment to quality, durabil-

ity, and performance.
This commitment begins with our research of the market,

including ‘Voice of the Customer’ contacts, ensuring we

make products that will satisfy your needs. Our Research

and Development facility then employs the world’s most

advanced technology to achieve the optimum operation of

our stoves, inserts and fireplaces. And yet we are old-fash-

ioned when it comes to craftsmanship. Each unit is meticu-

lously fabricated and surfaces are hand-finished for lasting

beauty and enjoyment. Our pledge to quality is completed

as each model undergoes a quality control inspection.
We wish you and your family many years of enjoyment in the

warmth and comfort of your hearth appliance. Thank you for

choosing Quadra-Fire.

and Welcome to the Quadra-Fire Family

!

SPÉCIFICATIONS DE LA VENTILATION:

MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de

minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en

usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides,

ou une cheminée de briques, avec espaces libres référés.

MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit

d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe

"A, ou une cheminée de briques, avec espaces libres alloués.

MAISON MOBILE: Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk

Metalbestos DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les

espaces libres pour mur double comme mentionné ci-bas.

MINIMUM CLEARANCES TO COMBUSTIBLES In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar.

LISTED ROOM HEATER, SOLID FUEL TYPE.

ALSO FOR USE IN MOBILE HOMES. (UM) 84 HUD .

"For Use with Solid Wood Fuel Only"

1445 N. Highway, Colville, WA 99114

www.quadrafire.com

Install and use only in accordance with

manufacturer's installation and operating

instructions. Contact local building or fire officials

about restrictions and installation inspections in

your area. Do not obstruct the space beneath

heater.

WARNING - For Mobile Homes: Do not install in

a sleeping room. An outside combustion air inlet

must be provided and unrestricted while unit is in

use. The structural integrity of the mobile home

floor, ceiling and walls must be maintained. The

stove needs to be properly grounded to the frame

of the mobile home. Components required for

mobile home installation: Outside Air Kit, Part

Number 831-1780.

Refer to manufacturer's instructions and local

codes for precautions required for passing

chimney through a combustible wall or ceiling and

maximum offsets.

Inspect and clean chimney frequently - Under

Certain Conditions of Use, Creosote Buildup May

Occur Rapidly.

Do not connect this unit to a chimney serving

another appliance.

Optional Components: Optional Blower, Part

831-1701.

Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.

Route power cord away from unit. Do not route

cord under or in front of appliance.

DANGER: Risk of electrical shock. Disconnect

power supply before servicing.

Replace glass only with 5mm ceramic available

from your dealer.

Do not use grate or elevate fire. Build wood fire

directly on hearth.

Do not overfire - if heater or chimney connector

glows, you are overfiring.

Operate only with the fuel loading door closed.

Open only to add fuel to the fire.

CAUTION

:

U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to

comply with July 1990 particulate emission standards.

2008 2009 2010 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.

PREVENT HOUSE FIRES

FLOOR PROTECTION

:

Floor protector must be a 3/8 inch min. thickness,

non-combustible material or equivalent, extending

beneath heater and to front/sides/rear as indicated

on the diagram below.

Exception: Non-combustible

floor protections must extend beneath the flue pipe

when installed with horizontal venting and extend 2

inches (51mm) beyond each side.

Report / Rapport

061-S-70-6

TESTED TO:/ TESTÉ À:

UL 1482, ULC S627-00.

Manufactured by:

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP

FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS

A

B

C

D

E

F

G

H

SINGLE WALL PIPE

15 (381) 11 (279) 21.5 (546) 13 (330) 8.5 (216) 17 (432) 56 (1422)

N/A

DOUBLE WALL PIPE

8.75 (222) 5.75 (146) 20 (508) 10.5 (267) 7.5 (191) 16 (406) 43 (1092)

N/A

SINGLE WALL PIPE

14 (356) 10 (254) 20.5 (521) 12 (305) 8.5 (216) 17 (432) 56 (1422) 9.5 (241)

DOUBLE WALL PIPE

9.5 (241) 5.5 (140) 21.5 (546) 13 (330) 7.5 (191) 16 (406) 43 (1092) 5 (127)

INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL 103 HT listed factory-built

Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48

inches (1220mm) with a minimum height of 43 inches (1092mm) to top of unit, and the referenced clearances.

DOUBLE WALL PIPE

9.5 (241) 5.5 (140) 21.5 (572) 13.5 (343)

N/A

N/A 43 (1092) 5 (127)

VENT SPECIFICATIONS:

SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or

blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney,
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air

insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a
masonry chimney and the referenced clearances
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree

Factory-built chimneys.

MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or
Security DL double wall connector pipe. Must be equipped with a spark arrestor.
Apply double wall clearances below when installing unit.

SERIAL NO. / NUMÉRO DE SÉRIE

2100 Millennium ACC

A

B

C

D

E

F

E

F

G

H

G

A

B

C

D

R

7039-134

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES

BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION:

APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE

COMBUSTIBLE SOLIDE, POUR USAGE DANS LES

MAISONS MOBILES. (UM) 84-64 HUD. "Pour Usage

Avec Bois Solide Seulement"

Installez et utilisez en accord avec les instructions

d'installation et d'opération du fabricant. Contactez le bureau

de la construction ou le bureau des incendies au sujet des

restrictions et des inspections d'installation dans votre

voisinage. Ne pas obstruez l'espace en dessous de l'appareil.

AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une

chambre à coucher. Un tuyau extérieur de combustion d'air

doit être installé et ne doit pas être obstrué lorsque l'appareil

est en usage. La structure intégrale du plancher, du plafond et

des murs de la maison mobile doit être maintenue intacte.

L'appareil de chauffage doit être fixé à la charpente de la

maison mobile. Les composants requis pour l'installation des

maisons mobiles: Assemblage d'air extérieur, Numéro de

Pièce 831-1780.

Référez vous aux instructions du fabricant et des codes

locaux pour les précautions requises pour passer une

cheminée à travers un mur ou un plafond combustibles, et les

compensations maximums.

Inspectez et nettoyez la cheminée fréquemment. Sous

certaines conditions, il se peut que la créosote s'accumule

rapidement.

Ne pas connecter cet appareil à une cheminée servant un

autre appareil.

Composants Optionnels: Ventilateur Optionnel, Pièce

#831-1701.

Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.

Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil

électrique au dessus ou en dessous de l'appareil.

DANGER: Il y a risque de décharge électrique. Déconnectez

le fil électrique de la prise de contact avant le service.

Remplacez la vitre seulement avec une vitre céramique de 5

mm disponible chez votre fournisseur.

N'élevez pas le feu. Bâtissez le feu de bois directement sur

l'âtre.

Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de

cheminée rougissent, vous surchauffez.

Opérez l'appareil seulement lorsque la porte de chargement

est fermée. Ouvrez la porte seulement lorsque vous devez

ajouter des combustibles dans le feu.

PRÉVENTION DES FEUX DE MAISON

PROTECTION DU PLANCHER

:

Le protecteur de plancher doit être d'un minimum de 3/8 inch

d'épaisseur, de matériel incombustible ou équivalent,

s'étendant du dessous de l'appareil de chauffage à l'avant,

aux cotés et à l'arrière comme indiqué sur le diagramme

suivant. Exception: Les protections incombustibles du

plancher doivent s'étendre en dessous du conduit de

cheminée lorsqu'installées avec une ventilation à l'horizontale

et s'étendre de 2 inches (51mm) de chaque côté.

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces &

(millimètres)

NOTE: Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de

l'entrée du conduit.

BACKWALL/SIDEWALL

MUR ARRIÈRE/MUR DE CÔTÉ

STOVE TO CEILING CLEARANCE
ESPACE LIBRE DU POÊLE AU PLAFOND

CORNER INSTALLATION

INSTALLATION DU COIN

ALCOVE TOP VIEW /

VUE DU HAUT DE L'ALCÔVE

ALCOVE SIDE VIEW /

VUE DE CÔTÉ DE L'ALCÔVE

CONDUIT DU MUR SIMPLE

CONDUIT DU MUR SIMPLE

C

ONDUIT DU MUR DOUBLE

CONDUIT DU MUR DOUBLE

INSTALLATION: FULL VERTICAL / ENTIÈREMENT VERTICALE

INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP

INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE

INSTALLATION: ALCÔVE - De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine 103HT de Classe "A", ou une

cheminée de briques. (Les maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de l'alcôve ne doit pas être de plus de 48 inches (1220mm) avec une

hauteur minimum de 43 inches (1092mm) du haut de l'appareil, et des espaces libres alloués.

CONDUIT DU MUR DOUBLE

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A./Fait Aux États-Unis

*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée

bâtit en usine.

Fabriqué par:

007004

16" from glass

8 in.

USA

Fuel loading door

5-3/4 in. 2-1/4 in."

29-5/8 in.

minimum

36 in.

minimum

CANADA

203mm (8 in.)

203mm

(8 in.)

203mm

(8 in.)

457mm (18 in.)

1168mm

(46 in.)

minimum

1078mm (42-7/16 in.)

minimum

O-T L

Tested and

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: BACK OF APPLIANCE

Serial No.

Model

Name

Test Lab &

Report No.

Mfg. Date

S A

M P

L E