Ac operation, 28 operation – HONDA GENERATOR EU2000i User Manual

Page 30

Advertising
background image

28

OPERATION

AC OPERATION

OUTPUT INDICATOR
(GREEN)

OVERLOAD INDICATOR
(RED)

20A RECEPTACLE

Before connecting an appliance to either generator, make sure that it is
in good working order and that its electrical rating does not exceed
that of the receptacle.
Most motorized appliances require more than their electrical rating for
startup. When an electric motor is started, the overload indicator (red)
may come on. This is normal if the overload indicator (red) goes off
within 4 seconds. If the overload indicator (red) stays on, consult your
generator dealer.

Start the engine (see page

)

and make sure the output
indicator (green) comes on.

Turn on the appliance.

If the generator is overloaded (see page

), or if there is a short circuit

in a connected appliance, the overload indicator (red) will go ON. The
overload indicator (red) will stay ON, and after about four seconds,
current to the connected appliance(s) will shut off, and the output
indicator (green) will go OFF. Stop the engine and investigate the
problem.

Determine if the cause is a short circuit in a connected appliance or an
overload. Correct the problem and restart the generator.