30

OPERATION

AC PARALLEL OPERATION

PARALLEL OPERATION CABLE
(optional equipment, see page 70)

Before connecting an appliance to either generator, make sure that it is
in good working order and that its electrical rating does not exceed
that of the receptacle.
Most motorized appliances require more than their electrical rating for
startup. When an electric motor is started, the overload indicator (red)
may come on. This is normal if the overload indicator (red) goes off
within 4 seconds. If the overload indicator (red) stays on, consult your
generator dealer.

Connect the parallel operation cable between the EU2000i
Companion to either an EU2000i or another EU2000i Companion
generator following the instructions supplied with the cable kit.

During parallel operation, the Eco-Throttle switch should be in the
same position on both generators.

Start the engines (see page

) and make sure the output indicator

(green) on each generator comes on (see page

).

1.

2.

23

28

09/02/17 17:16:12 31Z07700_031