Mt. Vernon Pellet Insert (AE)

C. Before Your First Fire

1. First, make sure your appliance has been properly installed

and that all safety requirements have been met. Pay
particular attention to the fire protection, venting and wall
control thermostat installation instructions.

2. Double check that the ash pan and firebox are empty and

then close the front door.

D. Starting Your First Fire

1. Fuel Selection

To start your first fire, you must select the appropriate fuel on
the FUEL SELECTION screen on the wall control to match the
fuel you have chosen to burn.

If the proper fuel is not selected your appliance will not operate
properly. For example, if you have selected wood pellets and
you are burning corn, the appliance may not light or may go out
or overfeed. Even if the correct fuel is already highlighted, press
“select” anyway to ensure proper initialization of the system.
Figure 24.3.

2. Comfort Level Selection

Once your fuel is selected, select the temperature at the desired
setting on the SET COMFORT LEVEL screen. Figure 24.4.

3. Automatic or Manual Setting

The automatic setting will control the heat output based on
the comfort level selection. The manual setting allows you to
manually control the heat output settings. See Ignition Cycles
on page 25.

NOTE: See the Wall Control Thermostat manual for detailed
instructions.

CAUTION

Tip of thermocouple must be in contact with the inside
end of the thermocouple cover

Missed ignitions can occur.

Figure 24.3

3. Auto-Clean Firepot System

Your appliance is equipped with an automatic firepot
cleaning system that will change the frequency of cleaning
based on the fuel being burned.

The auto-clean system will clean itself immediately on
initial plug in. If there is a power outage, as soon as power
is restored it will automatically clean itself.

Medium

Figure 24.2

Automatic

Manual
Off

Figure 24.1

Sunflower Seeds

Corn
Utility Pellet
Softwood Pellet

Wheat
Hardwood Pellet

DONE

SELECT

FUEL SELECTION

Figure 24.4

B. General Operating Information

1. Wall Control Thermostat - Automatic Setting

The appliance is like most modern furnaces; when the
wall control thermostat calls for heat, your appliance will
automatically light and deliver heat. When the room is up to
temperature and the wall control is satisfied the appliance
will shut down.

In the automatic setting the heat output level is controlled
by the wall control. Select “Automatic” on the AUTO/
MANUAL screen. Figure 24.1.

See Wall Control Thermostat Manual
for detailed operating instructions.

2. Wall Control Thermostat - Manual Setting

When you select “Manual” on the AUTO/MANUAL screen
the appliance will still automatically turn on and off
according to the temperature setting. However, you will
be able to manually control the heat output levels. Adjust
the heat output levels by using the HEAT OUTPUT LEVEL
screen.