Mt. vernon pellet insert (ae) – Hearth and Home Technologies MT VERNON Pellet Insert Advanced Energy (AE) MTVERNINSAE-MBK User Manual

Page 39

Advertising
background image

R

September 1, 2008

7036-135E

Page 39

Mt. Vernon Pellet Insert (AE)

17. Power Supply

The power supply is located at the bottom left side of the
appliance. It converts 120 volt AC current to 15 volt DC current
to power the appliance.

18. Overheat Sensor (Snap Disc)

The overheat sensor is mounted on the back of the drop tube
in the center of the appliance and has a reset button. To
access it remove the right side panel. If the fire tries to burn
back into the feed system or push exhaust up the feed tube,
this sensor will shut the appliance down, however the wall
control will continue to display messages. This sensor must
be manually reset. Disconnect power before resetting.

19. Thermocouple - Firepot
The thermocouple is located on top of the firepot inside
the thermocouple cover (ceramic protection tube). The
thermocouple sends a millivolt signal to the control board
telling the control board there is a fire in the firepot.

20. Thermocouple on Drop Tube

The thermocouple is located on the bottom of the drop tube
on the right side and is attached with a wing nut. It turns
the convection blower on and off, varies the speed of the
convection blower and will shut down the appliance if internal
heat exceeds set temperature.

21. Vacuum Switch

The vacuum switch is located on the right side of the
appliance under the feed motor behind the right side panel
and connects to the drop tube with a hose. This switch turns
the feed system on when vacuum is present in the firebox.
The vacuum switch is a safety device designed to shut off
the feed motor if the exhaust or the heat exchanger system
is dirty or plugged or if the firebox door is open.

22. Wall Control

The appliance is designed to run on a custom designed 3.3
volt DC thermostat wall control. It will not operate on any
other wall control. Refer to the instructions supplied with
the thermostat wall control.

23. Wiring Connections for Control Board

See Figure 39.1

24. Wiring Connection for Power Supply

See Figure 39.2.

Figure 39.1

Figure 39.2

120V AC in

120V AC out to
Control Board

15V DC out to
Control Board

Fuse 15A 250V

(need to remove

cover)

#

Description

1

Combustion Blower

2

Auto-Clean System

3

Feed/Auger Motors

4

Hopper/Door Switches

5

Auger/Auto Clean/Vacuum
Switches

6

Low Fuel

#

Description

7

Thermostat Wall Control

8

Combustion Blower (feedback)

9

Firepot Thermocouple

10

Drop Tube Thermocouple

n/a

Not Used

11

Convection Blower (feedback)

n/a

Not Used

#

Description

11

Convection Blower (feedback)

12

Igniter

13

AC Power In for Igniter

14

Convection Blower Power

15

Overheat Sensor (Snap Disc)

16

DC Power In from Power Supply

17

12 Volt Battery Back-up

17

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

n/a

Fuse 15A 120V,
under the cover

Fuse 15A 120V,
under the cover

Advertising