10

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

5

Flue Information

A. Flue Components

B. Use of Elbows

These models are approved to use Simpson Dura-Vent or
Hearth & Home Technologies series pipes, components and
termination. Approved components are labeled for identifi ca-
tion. This pipe is tested and listed as an approved compo-
nent of the stove.

DO NOT USE FIELD-FABRICATED FLUE COMPONENTS.

Refer to the flue manufacturer’s instructions.

This product is approved to be flued either horizontally,

through the side wall or vertically through the roof. You may

flue through a Class A or masonry chimney if an approved

adapter is used.

This gas stove is a balanced fl ue gas stove. All combus-
tion air must come directly from the outside of the building.
The fl ue pipe for this unit consists of an inner and an outer
pipe. The inner pipe carries the gas stove exhaust out of the
system, and the outer pipe brings fresh combustion air into
the gas stove.

Fire Hazard.

Explosion Risk.

Asphyxiation Risk.
Do NOT connect this gas gas stove to a chimney
fl ue serving a separate solid-fuel or gas burning
gas stove.

• Flue this gas stove directly outside.

• Use

separate

fl ue system for this gas stove.

May impair safe operation of this gas stove or
other gas stoves connected to the fl ue.

WARNING

Diagonal runs have both vertical and horizontal flue aspects

when calculating the effects. Use the rise for the vertical

aspect and the run for the horizontal aspect. (See Figure

5.1.)

Two 45° elbows may be used in place of one 90° elbow. On

45° runs, one foot of diagonal is equal to 21.6 cm horizon-

tal run and 21.6 cm vertical run. A length of straight pipe is

allowed between two elbows. (See Figure 5.1.)

Vertical

Horizontal

30.5 cm

21.6 cm

21.6 cm

Vertical and horizontal measurements were made using the
following standards.

C. Measuring Standards

CAUTION

ALL fl ue confi guration specifi cations MUST be followed.

• This product is tested and listed to these

specifi cations.

• Appliance performance will suffer if specifi cations are

not followed.

Figure 5.1

Pipe measurements are from center line to center line.

Horizontal terminations are measured to the outside of
the mounting surface (fl ange of termination cap). See
Figure 4.1 on page 8.

Horizontal pipe should be installed level with no rise.

A

round support box/wall thimble or heat shield

is

required when the fl ueing passes through a combus-
tible wall.

A

support box or ceiling fi restop

is required when the

fl ueing passes through a combustible ceiling.

Roof fl ashing and a storm collar are required when fl ue-
ing passes through the roof.

Follow instructions provided with the fl ueing for installa-
tion of these items.