INTELLIGUARD 9000™ SECURITY SYSTEM

74-3035—2

4

Control Center 2 Keypads

Each I9000 CU supports a

maximum of four Control

Center 2 (CC2) Keypads, two

per communication channel

maximum. Each CC2 displays

current system status and

allows local system control.

The operator can perform all

functions related to

programming, arming and

disarming any area at the CC2.

Features

• Automatically learned by the I9000 CU at power up.
• Can be programmed via DIP switch for no backlighting

or backlighting with auto shutoff after five minutes of

no activity.

• Tone volume programmable via DIP switch for Low or

High output.

• Supports four different addresses, programmable via

DIP switches.

Model: 8003-277 Control Center 2 Keypad.

Electrical Ratings:

Nominal Operating Voltage: 12 Vdc to 15 Vdc.

Operating Voltage: 10 Vdc to 18 Vdc.

Nominal Operating Current: 10 mA at 14.5 Vdc, no backlight-

ing, (107 mA with backlighting).

Annunciation: Two line by 24 character LDC display with

backlighting. Backlighting can be disabled to conserve

power. A red LED and a tone give the user visual and audi-

ble keystroke feedback.

Keypad: Membrane keypad with 20 keys.

Communication: RS-485 receiving and transmitting signals.

NOTE: Control Center 2 Keypads should be equally divided

among the two RS-485 communication lines to maxi-

mize system performance.

Enclosure: Plastic polycarbonate base, ABS plastic cover.

Dimensions: 6-7/8 in. (174 mm) wide x 3-3/4 in. (94 mm)

high x 1-1/4 in. (30 mm) deep.

Weight: 0.72 lb (0.33 kg).

Approvals: UL, ULC, CE.

Area Keypads

Each I9000 CU supports a

maximum of eight Area

Keypads. Each Area Keypad

(KID) shows the user if a

specific area is armed or

disarmed. The operator can

arm, disarm, force arm, or

partially arm a specific area at

the KID.

Features

• Serial numbered device—no address switch setting

required—learned through the KID Keypad in

conjunction with a CC2 Keypad or using PRO9000.

• Quick Reference guide (protruding from the top of the

KID) can be extended as required.

• Keypad insert can be used to identify the four

programmable LEDs at installation.

Model: 8003-220 Area Keypad.

Electrical Ratings:

Nominal Operating Voltage: 12 Vdc to 15 Vdc.

Operating Voltage: 10 Vdc to 18 Vdc.

Nominal Operating Current: 28.6 mA at 14.5 Vdc.

Annunciation: Six LEDs; Arm/Disarm status (bi-color), ID/

Code status (tri-color) and four red LEDs (control unit pro-

grammable), provide system feedback.

Keypad: Membrane keypad with 12 keys.

Communication: RS-485 receiving and transmitting signals.

NOTE: Area Keypads should be equally divided among the

two RS-485 communication lines to maximize sys-

tem performance.

Enclosure: Plastic polycarbonate base, ABS plastic cover.

Dimensions: 6-7/8 in. (174 mm) wide x 4-3/16 in. (106 mm)

high x 1-1/4 in. (30 mm) deep.

Weight: 0.66 lb (0.30 kg).

Approvals: UL, ULC, CE.

BIC-6 Input Concentrator

Each I9000 CU supports a maximum

of 62 input devices. The BIC-6

supports a maximum of six detection

or output devices. The BIC-6 transmits

information from the intrusion

detection devices to the CU.

The BIC-6 is a combination input/output device. It has six

loops. Each loop can be configured for input or output,

independently from the other loops in the BIC-6. Each loop

can be configured for normally open or normally closed

contacts. Each loop can be wired with or without an end-of-

line resistor (EOLR) depending on the loop type chosen. A

loop configured as an open collector output may be used to

drive an external LED directly (no external resistor required), a

low current/voltage device or a relay module if a higher drive

or isolation is required.

The BIC-6 can annunciate alarm or trouble in any loop on a 7-

segment LED local display independently of the control unit,

provided the corresponding BIC-6 parameter has been

enabled. If several loops are abnormal, the local display

automatically scrolls and displays all abnormal loops.