Multiple output module, Hall effect door switch, Features – Honeywell INTELLIGUARD 9000 User Manual

Page 6

Advertising
background image

INTELLIGUARD 9000™ SECURITY SYSTEM

74-3035—2

6

Communication: RS-485 receiving and transmitting signals.

Enclosures:

BIC-2 Input Module: Plastic polycarbonate. White with white

actuators.

BIC-2 HU Input Module: Plastic polycarbonate. White with red

actuators.

Dimensions: 5 in. (127 mm) wide x 1-3/4 in. (44 mm) high x

1 in. (25 mm) deep.

Weight: 2-7/8 oz (0.08 kg).

Approvals: UL, ULC, CE.

Multiple Output Module

The I9000 activates alarms

such as sirens, bells, lights, or

buzzers with the multiple

output module (MOM). Each

MOM activates a maximum of

eight alarms or notification

devices. The I9000 CU

supports four MOMs per

communication line for a

maximum of eight per system.

The MOM annunciates which outputs are active on a 7-

segment LED local display independently of the I9000 control

unit, provided the corresponding MOM parameter has been

enabled. If several outputs are active, the local display

automatically scrolls and displays all active outputs.

NOTE: The display indicates whether the function is active,

not whether the output is open or closed.

For installation or service, three onboard switches—in

conjunction with the LED display—allow the technician to

configure the unit. In this mode the MOM annunciates the

programmed output type for each output which can then be

modified using the switches.

Features

• Enclosure tamper switch.
• Eight independently programmable outputs—three

output types:

Output normally off—on when the I9000 linked

function is active.

Output normally on—off when the I9000 linked

function is active.

Output normally off—pulsates as long as the

I9000 linked function is active.

Interface is via three on-board push button

switches and the 7-segment display.

• Serial numbered device, no address switch setting

required—learned using the programming interface in

conjunction with a CC2 Keypad or using PRO9000.

• Tamper transmission status.

Model: 8003-286 Multiple Output Module (MOM).

Electrical Ratings:

Nominal Operating Voltage: 12 Vdc to 15 Vdc.

Operating Voltage: 10 Vdc to 18 Vdc.

Minimum Operating Current: 13.9 mA at 14.5 Vdc (outputs set

to Type 0 or 3, outputs not active, parameter 0 = 0, tamper

= normal, all switched loads powered separately).

Maximum Operating Current: 98.7 mA at 14.5 Vdc (all output

drivers powered on (outputs set to Type 0, outputs active)

parameter 0 = 1, tamper = normal, eight displayed,

switched loads powered separately).

Maximum Switched Current per Output: 50 mA externally

powered at 14.5 Vdc.

Maximum Output Terminal Voltage Drop: 1.0V (opto-coupler

in the ON state).

Maximum Output Terminal Voltage: 30V (opto-coupler in the

OFF state).

Annunciation:

Display: 7-Segment LED.

Information:

Communication Status: Unit must be in tamper alarm.

All active outputs: Unit must be in tamper alarm or the

respective parameter must be enabled.

Output Type: Normally open, normally closed, or pulsating

during local programming. Unit must be in tamper

alarm.

Communication: RS-485 receiving and transmitting signals.

Enclosure: Plastic polycarbonate base, ABS plastic cover.

Dimensions: 6-7/8 in. (1.74 mm) wide x 3-3/4 in. (94 mm)

high x 1 in. (25 mm) deep.

Weight: 0.64 lb (0.29 kg).

Approvals: UL, ULC.

Hall Effect Door Switch

Each Hall Effect Door Switch IV

(HEDS IV) is a high security

intelligent door contact/

detector. It consists of two

parts, the sensor (see photo—

right side) and the magnet

assembly (see photo—left

side). The sensor is mounted

on the door frame and the

magnet assembly attaches to the door. When the door opens,

the HEDS IV sends a signal directly to the I9000 Control Unit.

NOTE: Maximum gap permitted between the sensor and

magnet assemblies is 3/16 in. (4.76 mm).

Model: 8003-283 Hall Effect Door Switch IV (includes both

the 8003-280 and 8003-282).

Electrical Ratings:

Nominal Operating Voltage: 12 Vdc to 15 Vdc.

Maximum Operating Voltage: 10 Vdc to 18 Vdc.

Normal Operating Current: 7 mA at 14.5 Vdc.

Maximum Operating Current: 12 mA at 14.5 Vdc (learn

mode).

Weight: 0.68 lb (0.31 kg).

Accessory (optional): 8003-302 HEDS IV L Bracket (white

aluminum).

Approvals: UL, ULC, CE.

Advertising