Bic-2 input concentrator, Features – Honeywell INTELLIGUARD 9000 User Manual

Page 5

Advertising
background image

INTELLIGUARD 9000™ SECURITY SYSTEM

5

74-3035—2

For installation or service, three onboard switches—in

conjunction with the LED display—allow the technician to

configure the unit. In this mode, the BIC-6 annunciates the

programmed loop type for each loop which can then be

modified using the switches.

Features

• Enclosure tamper switch.
• Six independently programmable loops—four loop

types:

N.C. loop with EOLR.

N.O. loop with EOLR.

Output.

N.C. loop with no EOLR.

Interface is via three on-board push button

switches and the 7-segment display.

• Serial numbered device, no address switch setting

required—learned using the programming interface in

conjunction with a CC2 Keypad or using PRO9000.

• Status transmission (Alarm, Trouble, Tamper).

Model:

8003-238 Six Entry Concentrator (BIC-6) Module.

Electrical Ratings:

Nominal Operating Voltage: 12 Vdc to 15 Vdc.

Operating Voltage: 10 Vdc to 18 Vdc.

Minimum Operating Current: 16 mA at 14.5 Vdc (all loops

open).

Nominal Operating Current: 35 mA at 14.5 Vdc (all loops nor-

mal with a 2.2K ohm EOLR).

Maximum Operating Current (all input loops shorted, P0 = 1):

Normal Mode: 69 mA at 14.5 Vdc (type 2, 6 displayed).

Service Mode: 73 mA at 14.5 Vdc (type 4, 0 displayed).

Maximum Loop Distance: 250 ft (76m), 22 AWG (0.34 sq

mm), twisted pair cable. UL and ULC limit the distance to

50 ft (15m).

Typical Loop Output Drive Current:

Direct LED Drive: 5.5 mA (not included in operating cur-

rents above).

Relay or Other Device: 80 mA maximum at 14.5 Vdc or

Operating Voltage, whichever is less (not included in

operating currents above).

Typical of Loop Inputs:

Time to Trigger BIC-6 Input: 750 mS min.

Cleaning Current of Detector Contacts Connected to

Loops: 1 mA maximum.

Annunciation:

Display: 7-Segment LED.

Information:

Communication Status: Unit must be in tamper alarm.

All Loop Status: Unit must be in tamper alarm or the

respective parameter must be enabled.

Loop Type during Local Programming: Unit must be in

tamper alarm.

Communication: RS-485 receiving and transmitting signals.

Enclosure: Plastic polycarbonate base, ABS plastic cover.

Dimensions: 6-7/8 in. (174 mm) wide x 3-3/4 in. (94 mm)

high x 1-1/4 in. (30 mm) deep.

Weight: 0.62 lb (0.28 kg).

Approvals: UL, ULC, CE.

BIC-2 Input Concentrator

The BIC-2 supports a maximum of two

input (detection) and one output,

configured by the installer. The inputs

can be any standard detection device

such as a sensor or contact switch,

but must be normally open circuits. The output may be any

standard notification device such as a bell or light. The BIC-2

transmits information from the intrusion detection devices to

the CU.

Features

• Enclosure tamper switch.
• Serial numbered device, no address switch setting

required—learned using actuator buttons in

conjunction with a CC2 Keypad or using PRO9000.

• Status transmission (Alarm, Trouble, Tamper).
• Honeywell patented.

Models:

8003-242 BIC-2 Input Module with white actuator buttons. The

BIC-2 actuator buttons may be used as any push button

input to the system as required (except holdup). Push but-

ton activated by squeezing both white buttons at the same

time.

8003-284 BIC-2 HU Input Module with Hold-up Actuator. The

BIC-2 HU allows the user to send a distress signal to the

I9000 Control Unit by squeezing both red buttons at the

same time.

4545-059 Optional Relay for BIC-2. The optional relay for

BIC-2, or BIC-2 HU provides one normally open or nor-

mally closed dry contact.

NOTE: If using the relay option, loop 2 is not available on

either model.

Electrical Ratings:

Nominal Operating Voltage: 12 Vdc to 14.5 Vdc.

Operating Voltage: 10 Vdc to 15 Vdc.

Minimum Operating Current: 7.6 mA at 14.5 Vdc (both loops

normal, no optional relay, no output active, not polled or

idle).

Nominal Operating Current: 8 mA at 14.5 Vdc (both loops nor-

mal, 2.2K EOLR, no optional relay, no output active).

Maximum Operating Current: 31 mA at 14.5 Vdc (loop 1

shorted to ground, optional relay in closed position with

output active).

Maximum Loop Distance: 250 ft (76m), 22 AWG (0.34 sq

mm), twisted pair cable. UL and ULC limit the distance to

50 ft (15m).

Two loops jumper-programmable to a value of end-of-line

resistor (EOLR): 2.2K (as shipped) or 22K ohm. The

jumper affects both loops simultaneously.

Open Collector Output Switching Maximum: 20 mA at 14.5

Vdc or Operating Voltage, whichever is less.

One Optional Plug-in Relay Contact (normally open or nor-

mally closed): 30 Vdc at 1A.

Optional Relay Minimum Load Switching Current: 0.01 mA at

10 mV.

NOTE: If using the relay option, loop 2 is not available on

either model.

Annunciation: Red LED communication status indicator visi-

ble through one of the actuator buttons.