Hard Drive Installation and Replacement

Each SCSI channel on the controller supports up to 14 drives. Drives can be of the
Wide Ultra3 or Wide Ultra2 type.

Each drive on a SCSI bus must have a unique ID value in the range 0 to 15 (except
ID 7, which is reserved for controller use). This value is set automatically on hot-
pluggable drives in ProLiant servers and storage systems, but values for other drives
must be set manually.

• Do not terminate the drives. HP and Compaq branded servers and internal

cabling provide the required termination of the SCSI bus.

• Do not use drives of different capacity in the same array. The excess capacity of

larger drives cannot be used by the array and is wasted.

• Do not use hot-pluggable drives on the same SCSI bus as non-hot-pluggable

drives.

Hard drives that are currently supported by Smart Array controllers are listed at

www.hp.com/products/smartarray

.

General Information About Hard Drive Failure

When a hard drive fails, all logical drives that are in the same array will be affected.
Each logical drive in an array may be using a different fault-tolerance method, so
each logical drive can be affected differently.

• RAID 0 configurations cannot tolerate drive failure. If any physical drive in the

array fails, all non-fault-tolerant (RAID 0) logical drives in the same array will
also fail.