Codename: SilverHammer Part Number: 135606-005 Last Saved On: 10/8/02 11:26 AM

Table G-1: POST Error Messages

continued

Message

Description

Meaning and Recommended Action

1728

Slot x drive array – abnormal shutdown
detected with write cache enabled.

No array accelerator battery backup on
this model array controller.

Any data that may have been in array
accelerator memory has been lost.

This message should never occur unless
the write cache is somehow enabled on a
controller that does not have batteries.

1729

Slot 1 drive array – disk performance
optimization scan in progress – RAID
4/5 performance may be higher after
completion.

This message is normal after the initial
configuration of RAID 4 or RAID 5 logical
drives. After the parity data has been
initialized by ARM (an automatic process
that runs in the background on the
controller), this message goes away and
controller performance improves.

1753

Slot x drive array – array controller
maximum operating temperature
exceeded during previous power up.

This message appears at the next power-
up if the controller locks due to excessive
temperature. Check for proper operation of
the server cooling fan.

1754

Slot z drive array – RAID ADG drive(s)
configured but ADG Enabler Module is
detached or defective. Please check
for detached ADG Enabler Module.
Array accelerator is temporarily
disabled.

An operational ADG Enabler Module must
be attached whenever RAID ADG volumes
are configured or the array accelerator will
be disabled. Replace the ADG Enabler
Module.

1755

Slot z drive array – ADG Enabler
Module appears to be defective.
Please replace the ADG Enabler
Module.

Replace the defective ADG Enabler
Module, or remove it if it is not needed (that
is, if no RAID ADG logical drives are
configured).

1756

Slot x redundant controllers are not the
same model.

The redundant controllers are not of the
same model. Use two like model controllers
for redundancy.

1757

Slot x array accelerator daughterboard
incompatible. Please replace 4MB
array accelerator card with a 16MB or
64MB card.

The controller does not support the
attached array accelerator. Replace it with
the correct array accelerator.

continued