Adjust fan operation switch, as required, Adjust system on-time, as required – Honeywell MAGICSTAT CT2400 User Manual

Page 7

Advertising
background image

quick guide for operating or making changes follows:

NOTE: System switch must be set to Heat or Cool to perform the following:

Temp

u

Temporarily Change Temperature for Current Period

. Temporary indicator will

show on display; it will cancel itself at next scheduled change. To cancel sooner, press

Temp

Hold a Temperature Indefinitely—

,

0

press

to cancel.

14

-

-

-

.

Check Current Temperature Setting-

.

(If using Temporarily Change or Hold,

pressing this will cancel your change.)

Check Programs—

Run

repeatedly to see each time and temperature; then Program .

Time

(

Cancel a Program-

until program to cancel shows; then

together.

Beck

Permanently Change a Program—Repeat steps under Heating Program or Cooling Program
(pages 12 and 13) as applicable.

u

Return to normal program or start program —

.

Customer Assistance

Adjust Fan Operation Switch, As Required

The thermostat fan operation switch, labeled

electric heat system, set the switch to “E. The

FUEL SWITCH (see illustration on page 17) is

“E setting will allow the fan to turn on

factory-set in the “F position. This is the correct

with the heating or cooling in a system

setting for most systems. If your system is an

where the “G” terminal is connected.

Adjust System On-Time, As Required

The system on-tim

e

is

for a warm

air, gas or oil heating system. If you are installing

it on another type of system, the system on-time
must be adjusted accordingly by setting screws A
and B on the back of the thermostat. Use the
heating system table shown in the illustration,
(page 17) as a guide. The system on-time should

be optimized according to the type of system to

minimize room temperature swings. Setting the
screw “out one turn” means turning the screw

approximately 360° counterclockwise, or about
one complete turn.

In the unlikely event that you want longer furnace

on-time, readjust screws A and/or B as follows:

First, turn both screws in completely, then adjust

for system type:

Warm Air Furnace-Set at the Hot Water

setting, (A - out one turn, B - in).

Electric Furnace-Leave at the Warm Air

Furnace setting (A - in, B - in).

16

Advertising