Mount thermostat mounting plate – Honeywell MAGICSTAT CT2400 User Manual

Page 8

Advertising
background image

NOTE: This thermostat does not have a setting for steam/gravity air. Cycles would not be long

enough for accurate temperature control.

IMPORTANT: When using a high

efficiency furnace such as a
90 percent or greater Average
Fuel Utilization Efficiency
(AFUE) unit, adjust screw A
OUT ONE TURN and screw
B IN.

THERMOSTAT BACK

1

- - . . :

.

1
1
1
1
1
1
1
1

Y

I

FUEL SWITCH

1

1

- - - -

17

Mount Thermostat Mounting Plate

Position mounting plate on wall. Use a level

to make sure mounting plate is level. Use a

pencil to mark the two mounting holes.

(2)

18

— .

•l Remove mounting plate from wall, and drill

LEVEL

3/1 6 inch holes in wall (if drywall) as marked.

(

For firmer material such as plaster or wood,

)

drill 7/32 inch holes. Gently tap anchors
(provided) into drilled holes until flush with the
wall.

Reposition mounting plate over holes,

pulling wires through wiring opening. Loosely
insert two mounting screws into holes.

Level for appearance only; thermostat will

function properly even when not level. Tighten
mounting screws.

M1714A

19