Esp control – Harman Stove Company R6 User Manual

Page 13

Advertising
background image

13

ESP CONTROL

Feed adjuster
Sets the maximum feed
rate

Test
Runs all motors at
full speed for two
minutes to check
operation. After two
minutes the stove
will go to minimum
burn and the blowers
will alternate from
high to low every two
minutes to remind
you that you are still
in "Test Mode".

Distribution Blower
speed adjustment range.

Status light error messages:

1 Blink: Indicates control board self diagnostic fail-
ure. This requires a manual reset*.
2 Blinks: Indicates that the feeder position switch
has not sensed the slide plate in the home position
for 30 minutes. This means that the slide plate may
be stuck due to a foreign object in the fuel or the
switch has failed. If the switch has failed the stove
will operate normally, however if turned to the "OFF
" position the stove will go to minimum burn and will
only shut down when it runs out of fuel. If the slide
plate frees itself the status light will automatically

reset. If the error continues call your Harman Dealer.
3 Blinks: Indicates ESP (Exhaust Sensing Probe)
failure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed.
If a Room Sensing Probe is then installed the status
light will automatically reset.
(Note) only after unit has warmed up.

* Manual reset, disconnect power cord for a few
seconds and reconnect. If error still occurs call your
Dealer.

Temp dial
Allows you to adjust the Room temperature
in Room Temp Mode using the outer scale
marked in degrees Fahrenheit. It also
allows you to adjust the stove temperature
while in Stove Temp Mode using the inner
scale marked from 1 to 7.

Mode Selector
Allows you to choose between Room
Temp Mode, Stove Temp Mode, or OFF.
Also allows you to vary the distribution
blower speed by turning the knob to the
high or low side of each mode.

Power Light
Indicates power to the
control.
Secondary function:
Blinks every 15 seconds
when the feed adjuster is
in "Test Mode". This
verifies feeder switch
operation. Should be lit
anytime the unit is pluged
in.

Indicates Power to the
feed motor.

Indicates Power to
combustion blower

Status Light
Will be lit in either stove
or room temp mode when
pointer is not within off
position band except after
normal shut down. Blinks
to indicate errors listed
listed below.

Indicates power to
distribution blower.