2 preferred method, 1 preferred method, Caution – Harman Stove Company R6 User Manual

Page 6

Advertising
background image

6

#2 Preferred method

This method also provides excellent venting for

normal operation but requires the stove to be installed
farther from the wall. The vertical portion of the vent
should be three to five feet high and at least three
inches from a combustible wall. This vertical section
will provide natural draft in the event of a power fail-
ure.

#1 Preferred method

This method provides excellent venting for nor-

mal operation and allows the stove to be installed
closest to the wall. Two inches from the wall is safe,
however, four inches allows better access to remove
the rear panel. The vertical portion of the vent should
be three to five feet high. This vertical section will
provide natural draft in the event of a power failure.

Fig. 5

Fig. 6

KEEP COMBUSTIBLES (SUCH

AS GRASS, LEAVES, ETC.) AT

LEAST 3 FEET AWAY FROM THE

FLUE OUTLET ON THE

OUTSIDE OF THE BUILDING.

CAUTION

3 ft.

to combustibles

3 ft.

to combustibles