Heath Zenith DUAL BRITE SL-5597 User Manual

Dual brite, Motion sensor light control for canadian tire, Operation

Advertising
background image

© 2003 DESA Specialty Products™

598-1038-03

Dual Brite

Motion Sensor
Light Control for
Canadian Tire

Model SL-5597

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Brite™ Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

2 Wire

Connectors

Gasket

6 Screws

(3 sizes included)

Light Control

Requirements

• The Light Control requires 120-volts AC.
• If you want to use the Manual Mode, the control must

be wired through a switch.

Some codes require installation by a qualified

electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Mounting Strap

Mounting Bolt

2 Lamps

(installed)

OPERATION

* resets to Auto Mode at dawn.

TEST

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to

Dawn

DUAL BRITE™

Put ON-TIME switch
on the sensor bottom
to TEST and the Dual
Brite™ switch OFF.

MANUAL MODE

ON-TIME

TEST 1 5 20

... back on.

AUTO

1 Second OFF

then...

Dual Brite™ TIMER

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light
turns on full bright for the ON-TIME (1,5, or 20 minutes)
then returns to dim mode.

Move ON-TIME Switch to

1, 5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.

Rubber Plug

Plastic Hanger

Cover

Plate

Sensor

Lamp

Holders

This package includes:

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Auto

1, 5, 20 min.

x

Manual

Until Dawn*

x

Advertising