SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 70 ft. (21 m); 100

ft.(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . . . . Up to 240

°

Electrical Load . . . . . . . . Up to 200 Watts Maximum

Incandescent (Up to 100
Watts Maximum each lamp
holder.)

Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . . 1 , 5, 20 minutes
Dual Brite™ Timer . . . . . 3, 6 hours, Dusk-to-Dawn
Replacement lamp . . . . T4 100W, G8 halogen bi-pin

120 VAC

DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.

Loosen the clamp screw in the
sensor ball joint and gently ro-
tate the sensor.

Walk through the coverage area
noting where you are when the
lights turn on. Move the sensor
head up, down, or sideways to
change the coverage area.
Keep the sensor at least 2"
(51 mm) away from the lamps.

Adjust the RANGE as needed.
Too much range may increase
false triggering. Range Boost
increases coverage up to 100
feet.

Secure the sensor head's aim
by tightening the clamp screw.
Do not overtighten the screw.

Set the amount of TIME you
want the lights to stay on after
motion is detected (1, 5, or 20 minutes).

Set the DUAL BRITE™ switch to the amount of time
after dusk you want the lights on at low level (Off, 3,
6 Hrs., Dusk-to-Dawn).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Maximum

Range

240

°

Maximum

Coverage Angle

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

The control is most sensitive to motion across it.

Least Sensitive

Most Sensitive

Motion

Sensor

Motion

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE:

Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on or when switching modes wait 1

1

/

2

minutes.

Bottom of Sensor

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME

DUAL BRITE

TEST 1 5 2 0

MINUTES

OFF 3 6 DUSK TO

HOUR DAWN

Turn the RANGE control to the mid position, Dual
Brite™ to OFF and the ON-TIME control to the
TEST position.

70 ft.

100 ft.

(21 m) (30.5 m)

Boosted

8 ft.

(2.4 m)