16

TECHNICAL DETAILS

Model

Cooker 60 80 100 120

Rated input kw (gross)

17.6

22.2

29.7

37.3

45.5

Rated output kw (gross)

-

17.6

23.4

29.3

35.2

Burner

Cooker

Boiler - 60k

Boiler - 80k

Boiler - 100k

Boiler - 120k

Gas Volume m 3/jr

1.68

2.11

2.84

3.56

4.34

Co2 %

8.5-9.0

7.0-8.0

8.0-8.5

8.5-9.0

8.5-9.0

Starting current - Amp

0.422

0.422

0.8

0.8

0.83

Running current - Amp

0.33

0.33

0.48

0.48

0.74

Electrical power consumption

230v 50 Hz 95 watts

Gas Type

Natural Gas 20mbar G20

Gas Cat

I

2H

for use in GB, IE (Great Britain and Eire)

Weight - dry kg

512kg

Water content - Litre

38

Flow and Return

NA

2 x 1

1/4”

BSP

Max Operating Pressure (PMS)

NA

3.0 bar

Operating Temparature Range

NA

60 - 80°C

Conventional Flue

0.05 +/- 0.02” WG

Operating Range

12.45 +/- 4.98 Pa

Water side resistance - mbar
10°C diff

NA

26

20°C diff

NA

8.3

Flue sockets - Dia. 145mm

Inside Flue Dia. 5” (125mm)