Checking the drainage – Heat Controller DMH24DB-1 User Manual

Page 29

Advertising
background image

Service Manual 29

Checking the Drainage, Forming the Pipings and Long Pipe Setting

Checking the drainage

To check the drainage.

1. Pour a glass of water on the evaporator.

2. Ensure the water flows through the drain hose of the

indoor unit without any leakage and goes out the drain exit.

Drain piping

1. The drain hose should point downward for easy drain flow.

2. Do not make drain piping.

Downward slope

Do not raise

Accumulated
drain water

Tip of drain hose
dipped in water

Air

Waving

Water
leakage

Water
leakage

Ditch

Less than
50mm gap

Water
leakage

Checking the Drainage, Forming the Pipings and Long Pipe Setting

Advertising