Hotpoint SD97PC User Manual

Page 16

Advertising
background image

GB

16

Electrical connection
The electrical connection to the mains must be made on
the appliance. The power voltage and frequency are as
indicated on the rating plate.
WARNING: THIS APPLIANCE MUST BE EARTHED.

Mounting the power supply cable
To open the terminal board:

Using a screwdriver, press on the tabs situated on each
side of the terminal board cover.

Pull open the terminal board cover.

To mount the power supply cable, proceed as follows:

Unscrew the cable clamp screw and the contact
screws.

Position the jumpers accordingly to the type of
connection you wish to make as per the diagrams
below.

Note: The jumpers are factory set for a 230V single
phase connection.

Fasten the power supply cable in the corresponding
cable clamp and close the cover.

Power cable supply connection to the electrical
mains:
We recommend you use a power supply cable which is
long enough to allow you to take the oven out of its recess
in the event of maintenance operations (only use HAR - H
05 - RRF quality cables fitted with a plug conforming to
the regulations in force.
The plug must be accessible at all times.

Unplug the appliance before all operations, even when
replacing the oven lamp.

Using the appliance without correct earthing is highly
dangerous.

IMPORTANT:
After connecting the appliance to the flexible cable, tighten
all the screws on the terminal board.

This appliance conforms to the following EEC Directives:

Low Voltage Equipment
73/23/EEC
93/68/EEC

Electromagnetic Compatibility
89/336/EEC
93/68/EEC

Inner dimensions of the oven:
width

43.5cm

depth

40.0cm

height

32.0cm

Inner volume of the oven:

54 litres

Voltage and frequency of power supply:

230-240V

50-60Hz

2250-2400W

Electrical Connections:

Voltage Frequency: 230 V-1+N - 50Hz

Fuse Section: 32A - 4mm

3

You can connect your oven to the system means of a
terminal board. Refer to above information for the minimal
cable sections and the calibration of the protective
elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minimum contact
opening of 3mm - should be installed between the
appliance and the mains.

Electrical Connection

L

N

1

2

3

4

5

Advertising
This manual is related to the following products: