Heat & Glo Fireplace COSMO-I30 User Manual

Page 14

Advertising
background image

Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev. H • 1/11

14

Burner Ignition and Operation

Frequency: Annually

By: Service Technician

Tools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a
manometer.

• Verify burner is properly secured and aligned with pilot

or igniter.

• Clean off burner top, inspect for plugged ports, corrosion

or deterioration. Replace burner if necessary.

• Verify batteries have been removed from battery back-up

IPI systems to prevent premature battery failure or
leaking. For optimal battery life, locate the battery
pack outside of the control cavity on the hearth. This
placement will reduce the chances of overheating the
batteries during extended burns which could result in
reduced battery life or degradation.

• Check for smooth lighting and ignition carryover to all

ports. Verify that there is no ignition delay.

• Inspect for lifting or other fl ame problems.

• Verify air shutter setting is correct. See Section 12.G for

required air shutter setting. Verify air shutter is clear of
dust and debris.

• Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce

size is correct. See Service Parts List for proper orifi ce
sizing.

• Verify manifold and inlet pressures. Adjust regulator as

required.

• Inspect pilot fl ame pattern and strength. See Figure 3.1

for proper pilot fl ame pattern. Clean or replace orifi ce
spud as necessary.

• Inspect thermocouple/thermopile or IPI fl ame sensing rod

for soot, corrosion and deterioration. Clean with emery
cloth or replace as required.

• Verify that there is not a short in fl ame sense circuit by

checking continuity between pilot hood and fl ame sense
rod. Replace pilot as necessary.

(IPI only)

Figure 3.1 IPI Pilot Flame Patterns

Advertising