Fireplace size requirements – Heat & Glo Fireplace COSMO-I30 User Manual

Page 17

Advertising
background image

17

Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev. H • 1/11

5

5

Fireplace Size Requirements

Figure 5.1 Fireplace Opening

In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).

E

D

C

I

B

A

G

H

F

MINIMUM FIREPLACE SIZE

Location

COSMO-I35

COSMO-I30

Inches

Millimeters

Inches

Millimeters

A

Rear Width

23-1/2

597

20-1/4

514

B

Front Width

34-5/8

879

30-1/2

775

C

Glass Opening Width

31-9/16

802

27-7/16

697

D

Glass Opening Height

15-11/16

398

12-13/16

325

E

Height-Front

24

610

20-1/2

521

F

Height-Rear

21-1/16

535

17-5/8

448

G**

Unit Depth

16

406

14-3/4

375

H

Venting Depth

10-1/2

267

9-1/2

241

I

Height to Top of
Glass Frame

22

559

18-1/4

464

* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum

fi replace height for bends in vent pipe.

A. Minimum Fireplace Opening

Minimum fi replace opening requirements for a standard 3/4
inch deep surround are shown in Figure 5.1. For smaller
openings, an optional 1-1/2 inch deep surround is available
and dimensions are shown in Figure 5.2.

WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traffi c and away from furniture and draperies.

• The fi rebrick (refractory), glass doors, screen rails, screen

mesh and log grates can be removed from a factory
built fi rebox in order to gain minimum gas insert opening
requirements.

• Any smoke shelves, shields and baffl es may be removed

from the factory built fi rebox if attached with mechanical
fasteners.

• The metal fl oor of the solid fuel fi rebox may be removed to

facilitate the installation of the insert. The appliance may
not be placed directly on the base of the outer wrap, a 1/4
inch airspace must be provided between the insert and
the fl oor of the outer wrap. Use the levelling legs to raise
the insert a minimum of 1/4 inch. The original fi replace
may never be returned to solid fuel in this condition.
The sidewalls and top structure of the fi rebox may not
be altered with the exception of removable baffl es and
dampers.

• Cutting of any sheet metal parts of the fi replace in which

the gas fi replace insert is to be installed is prohibited,
except the fl oor as tested for and as noted above.

TOP VIEW

FRONT VIEW

**Unit depth is measured to the back of the surround to give the depth needed for installation.