Standard Nozzle Selection

Model RLC

Air Defrost

Model

No. of

Fans

Distributor Tube (in.)

No. of

Circuits

R-404A

R-22

OD

Length

RLC040

1

3/16

15

1

-

-

RLC052

1

3/16

15

1

-

-

RLC065

1

3/16

15

2

L-1/2

L-1/3

RLC070

2

3/16

15

2

L-1/2

L-1/3

RLC090

2

3/16

15

3

L-3/4

L-1/2

RLC104

2

3/16

15

3

L-3/4

L-1/2

RLC120

2

3/16

15

3

L-1

L-3/4

RLC130

2

3/16

15

4

L-1

L-3/4

RLC140

3

3/16

15

4

L-1

L-3/4

RLC156

3

3/16

15

5

L-1-1/2

L-1

RLC180

3

3/16

15

5

L-1-1/2

L-1

RLC208

4

3/16

15

5

L-1-1/2

L-1

RLC260

5

3/16

15

9

L-2

L-1-1/2

RLC312

6

3/16

15

9

L-2-1/2

L-2

RLC370

6

3/16

15

10

L-3

L-2

Model ELC/EFC

Electric Defrost

Model

No. of

Fans

Distributor Tube (in.)

No. of

Circuits

Low Temp.

-30°F to 0°F SST

-34°C to -18°C SST

Medium Temp.

10°F to 25°F SST

-12°C to -4°C SST

OD

Length

R-404A

R-22

R-404A

R-22

6 F

ins P

er I

nch

ELC035

1

3/16

15

2

L-1/2

L-1/4

L-1/3

L-1/4

ELC040

1

3/16

15

2

L-1/2

L-1/4

L-1/3

L-1/4

ELC047

1

3/16

15

2

L-1/2

L-1/3

L-1/3

L-1/3

ELC065

2

3/16

15

4

L-3/4

L-1/2

L-1/2

L-1/2

ELC075

2

3/16

15

4

L-1

L-3/4

L-3/4

L-1/2

ELC090

2

3/16

15

5

L-1

L-3/4

L-3/4

L-1/2

ELC120

3

3/16

15

5

L-1-1/2

L-1

L-1

L-3/4

ELC140

3

3/16

15

6

L-1-1/2

L-1

L-1-1/2

L-1

ELC160

4

3/16

15

8

L-2

L-1

L-1-1/2

L-1

ELC180

4

3/16

15

10

L-2

L-1-1/2

L-1-1/2

L-1

ELC200

5

3/16

15

9

L-2-1/2

L-1-1/2

L-2

L-1-1/2

ELC240

6

3/16

15

9

L-2-1/2

L-2

L-2

L-1-1/2

ELC280

6

3/16

15

10

L-3

L-2

L-2-1/2

L-2

4 F

ins P

er I

nch

EFC041

1

3/16

15

2

L-1/2

L-1/3

L-1/3

L-1/4

EFC068

2

3/16

15

4

L-3/4

L-1/2

L-1/2

L-1/3

EFC080

2

3/16

15

4

L-1

L-3/4

L-3/4

L-1/2

EFC102

3

3/16

15

5

L-1

L-3/4

L-3/4

L-3/4

EFC136

4

3/16

15

8

L-1-1/2

L-1

L-1

L-3/4

EFC170

5

3/16

15

8

L-2

L-1-1/2

L-1-1/2

L-1

EFC204

6

3/16

15

8

L-2-1/2

L-1-1/2

L-2

L-1-1/2

EFC235

6

3/16

15

10

L-2-1/2

L-2

L-2

L-1-1/2

Model GLC

Hot Gas Defrost

Model

No. of Fans

Distributor Tube (in.)

No. of

Circuits

Low Temp.

-30°F to 0°F SST

-34°C to -18°C SST

Medium Temp.

10°F to 25°F SST

-12°C to -4°C SST

OD

Length

R-404A

R-22

R-404A

R-22

6 F

ins P

er I

nch

GLC035

1

1/4

15

2

J-1/2

J-1/4

J-1/3

J-1/4

GLC040

1

1/4

15

2

J-1/2

J-1/3

J-1/3

J-1/4

GLC047

1

1/4

15

2

J-3/4

J-1/3

J-1/2

J-1/4

GLC065

2

1/4

15

4

J-1

J-1/2

J-3/4

J-1/3

GLC075

2

1/4

15

4

J-1

J-3/4

J-3/4

J-1/2

GLC090

2

1/4

15

5

G-1-1/2

G-3/4

G-3/4

G-1/2

GLC120

3

1/4

15

5

G-1-1/2

G-1

G-1

G-3/4

GLC140

3

1/4

15

6

G-2

G-1

G-1-1/2

G-1

GLC160

4

1/4

15

8

G-2

G-1-1/2

G-1-1/2

G-1

GLC180

4

1/4

15

10

E-2-1/2

E-1-1/2

E-1-1/2

E-1

GLC200

5

1/4

15

9

E-2-1/2

E-2

E-2

E-1-1/2

GLC240

6

1/4

15

9

E-3

E-2

E-2

E-1-1/2

GLC280

6

1/4

15

10

E-4

E-2-1/2

E-2-1/2

E-2

4 F

ins P

er I

nch

GLC041

1

1/4

15

2

J-1/2

J-1/3

J-1/3

J-1/4

GLC068

2

1/4

15

4

J-1

J-1/2

J-3/4

J-1/2

GLC080

2

1/4

15

4

J-1

J-3/4

J-3/4

J-1/2

GLC102

3

1/4

15

5

G-1-1/2

G-3/4

G-1

G-3/4

GLC136

4

1/4

15

8

G-2

G-1

G-1-1/2

G-1

GLC170

5

1/4

15

8

G-2

G-1-1/2

G-1-1/2

G-1

GLC204

6

1/4

15

8

G-2-1/2

G-2

G-2

G-1-1/2

GLC235

6

1/4

15

10

E-3

E-2

E-2

E-1-1/2

Advertising