Technical specifications, Quickspecs – HP Server Blades BL30p User Manual

Page 32

Advertising
background image

ProLiant BL p-Class
Server Blade Enclosure
with enhanced backplane
components

Dimensions

Height

10.5 in (26.67 cm)

Width

17.60 in (44.70 cm)

Depth

28.86 in (73.30 cm)

Input Specifications

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

Rated input current

125 A at -48 VDC

Rated input Power

6000 W

Individual Server Blade
Bay Ratings

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

Rated input current

14.6 A at -48 VDC

Rated input Power

700 W

Temperature Range

Operating

50° to 95° F (10° to 35° C)

Non-Operating

-22° to 140° F (-30° to 60° C)

Relative Humidity
(non-condensing)

Operating

20% to 80%

Non-Operating

5% to 95%

Wet Bulb Temperature

Operating

82.4° F (28° C)

Non-Operating

101.7° F (38.7° C)

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.

Operating and
Performance
Specifications for ProLiant
BLp-Class RJ-45 Patch
Panel 2 with Fiber Channel
pass through

Dimensions

Height

10.405 in (26.43 cm)

Width

1.535 in (3.899 cm)

Depth

27.697 in (70.35 cm)

Capability

IEEE 802.2, 802.3, 802.3u

Network Transfer Rate

10 Base-T (half-duplex)

10 Mbps

10 Base-T (full-duplex)

20 Mbps

100 Base-TX (half-duplex)

100 Mbps

100 Base-TX (full-duplex)

200 Mbps

1000 Base-TX (full-duplex)

1000 Mbps

Fiber Channel SAN

Velio VC1070 re-timer

Auto-rate negotiate between 2G and 1G

Connector

Network

32 RJ-45 in the back.

Fiber Channel SAN

16 Pluggable SFP optical cages in the front

Cable Support

10 Base-TX

Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)

100 Base-TX

Category 5 UTP (2 pair); up to 328 ft/100 m

1000 Base-TX

Category 5E (4 pair); up to 328 ft (100 m)

Fiber Channel

SFP optical cable

EMI

FCC Class A

ICES-003 Class A

AS/NZS 3548 Class A

VCCI Class A

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.

QuickSpecs

HP ProLiant BL30p Server Blade

Technical Specifications

DA - 11958 North America — Version 6 — September 24, 2004

Page 32

Advertising