Quickspecs – HP Server Blades BL30p User Manual

Page 36

Advertising
background image

Operating and
Performance
Specifications for
ProLiant BL p-Class
Power Enclosures

Single-Phase Model

3-Phase Model

Dimensions

Height

5.25 in (13.34 cm)

5.25 in (13.34 cm)

Width

27.15 in (68.96 cm)

27.15 in (68.96 cm)

Depth

17.60 in (44.7 cm)

17.60 in (44.7 cm)

Weights

No Hot-Plug
Power Supplies

47.5 lb (21.55 kg)

47.5 lb (21.55 kg)

All Hot-Plug
Power Supplies

99.5 lb (45.13 kg)

125.5 lb (56.93 kg)

Input Requirements

Rated input voltage

200 VAC to 240 VAC

200 VAC to 240 VAC line
to line

Rated input frequency

50 Hz to 60 Hz

50 Hz to 60 Hz

Rated input current
per side

24A

24A per phase

Rated input power
per side

5760 W

9976 W

Power cord

1 NEMA L6-30P per side

1 NEMA L15-30 per side

Output Voltage
Specifications

Rated output voltage

-48.8 VDC to -54 VDC

-48.8 VDC to -54 VDC

Rated output current

99A

170A

Rated output power

4298 W

8310 W

Nominal power

4158 W at 208 VAC

7202 W at 208 VAC

Ambient Temperature
Range

(See NOTE)

Operating

50° to 95° F
(10° to 35° C)

50° to 95° F
(10° to 35° C)

Shipping

-22° to 140° F
(-30° to 60° C)

-22° to 140° F
(-30° to 60° C)

Relative humidity,
non-condensing

(See NOTE)

Operating

20% to 80%

20% to 80%

Non-operating

5% to 95%

5% to 95%

Wet Bulb
Temperature

Operating

82.4° F (28° C)

82.4° F (28° C)

Non-operating

101.7° F (38.7° C)

101.7° F (38.7° C)

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.

QuickSpecs

HP ProLiant BL30p Server Blade

Technical Specifications

DA - 11958 North America — Version 6 — September 24, 2004

Page 36