Quickspecs – HP Server Blades BL30p User Manual

Page 35

Advertising
background image

Operating and
Performance
Specifications for ProLiant
BL p-Class GbE2
Interconnect Switch

Dimensions

Height

10.405 in (26.43 cm)

Width

1.535 in (3.899 cm)

Depth

27.697 in (70.35 cm)

Weight

12.0 lb/5.4 kg per interconnect switch

Performance

24 Gbps External port bandwidth per server blade enclosure (full duplex)

Forwarding rate 1.5 million pps per gigabit port (64-byte packets)

Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support

Forwarding Mode

Store and forward

MAC Addresses

2,048 per interconnect switch

Forwarding Table
Age Time

Maximum age: 1 to 65535 seconds; default: 300 seconds

Memory

128MB Main, 32MB flash and 2MB packet buffer per interconnect switch

Compliance

IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.3ac, 802.3ad
(Static), and 802.1Q

SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB
(RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC
2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC
1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP
Enterprise Switch MIBs and Environmental Traps

RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5,
NTP v2 (RFC 1119), BootP client (RFC 2132), and XModem

Network Transfer
Rate

10 Base-T (half-duplex)

10 Mbps

10 Base-T (full-duplex)

20 Mbps

100 Base-TX (half-duplex)

100 Mbps

100 Base-TX (full-duplex)

200 Mbps

1000 Base-TX (half-duplex)

1000 Mbps

1000 Base-TX (full-duplex)

2000 Mbps

1000 Base-SX (full-duplex)

2000 Mbps

Connector

12 RJ-45, 2 DB-9 (C-GbE2 Interconnect Kit)
8 LC fiber, 4 RJ-45, 2 DB-9 (F-GbE2 Interconnect Kit)

EMI

FCC Class A

ICES-003 Class A

AS/NZS 3548 Class A

VCCI Class A

Safety

UL/CUL Listed Accessory

CE

Power
Requirements

48VDC: 2040 mA, 98 W maximum (per interconnect switch without GbE2 Storage
Connectivity Kit)
48VDC: 2355 mA, 113 W maximum (per interconnect switch with GbE2 Storage
Connectivity Kit)

Temperature
Range

Operating

50° to 95° F (10° to 35° C)

Non-operating

-22° to 140° F (-30° to 60° C)

Relative Humidity
(non-condensing)

Operating

20% to 80%

Non-operating

5% to 95%

Wet Bulb
Temperature

Operating

82.4° F (28° C)

Non-operating

101.7° F (38.7° C)

NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper
operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4
psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for
storage is 70 KPa.