A’ = available – Heatcraft Refrigeration Products HCS User Manual

Page 10

Advertising
background image

10

* The percentage means the belts can handle an extra 20% or 50% BHP.

Available on:

Available on:

Accessories for Fan and Coil Sections

Fan Section Accessory:
Forward curved blower for total static of 3.5" to 6" ........................................................................Models 03 - 18 for all cabinet styles
Internal spring isolation (discharge arrangement 2 and 3 only).......................................................All models except size 14 and VCS cabinets
Internal spring isolation (discharge arrangement 2, 3, 4, 5 only) ....................................................All VCS cabinets except size 14
Inlet vanes (does not include damper motor), forward curve (FC) ..................................................Models 20 - 41 for all cabinet styles
Inlet vanes (does not include damper motor), air foil (AF) fan .......................................................Models 20 - 75 for all cabinet styles
Dual drive (extended shaft blowers with motors and drives
installed on each side of fan, select 2 motors and 2 drives .........................................................Models 20 - 75 for all cabinet styles

Coil Section Accessory:

Available on:

Large face area and small face area coils (see pages 42 & 43) ........................................................All HCS, HCL, HD, and VCS coil cabinets
Balancing dampers above small coil (to adjust air flow over coil in the field) ................................All HCS, HCL, HD, and VCS cabinets
Blank off plate above small sized coil (to force entire air flow over coil) .......................................All HCS, HCL, HD, and VCS cabinets
Stainless steel drain pan (in coil sections)....................................................................................... All HCS, HCL, HD, and VCS coil cabinets
Coil section access door (standard section has removable panels) ..................................................All HCL and VCS coil cabinets
Coil spacer, a preheat coil can be spaced apart from a cooling coil with a
coil spacer, the spacer prevents air bypass around the downstream
coil. The standard spacer is 6" wide and is furnished with a 4" x 6" .......................................All HCL and VCS coil cabinets
removable inspection plate. See below for reheat coil.
Mount reheat coil to leaving air side of section (see page 38).................. .......................................All HCL and VCS coil cabinets

Gaskets
Gaskets between sections......................................................................................... ........................All HCS, HCL, HD, and VCS cabinets
Gaskets between sections and gasketed panels (outdoor application)..........................Available on all five cabinets

Double Wall:
Double wall construction, adds 4" to the width and 2" to the height and length of
cabinet. Insulation is 2" of fiberglass at 1.5 lbs per cubic foot density.

Available on all five

The insulation is sandwiched between the standard unit and the outer skin.

fan and coil cabinets

Motors are three phase, ball bearing, rigid base and belt duty.

‘A’ = Available

Available Motors, Drives, Motor Starters per Horsepower

Motor

Drive*

Starter

Motor Horsepower

Description

1

1.5

2

3

5

7.5

10

15

20

25

30 40

50

Open single speed motor, EPAct

A

A

A

A

A

A

A

A

A

A

A

A

A

Totally enclosed fan cooled (TEFC) motor, EPAct

A

A

A

A

A

A

A

A

A

A

A

A

A

Open 2 speed 2 winding, 1800-1200 RPM motor

A

A

A

A

A

A

A

A

A

A

Open single speed premium high efficiency motor

A

A

A

A

A

A

A

A

A

A

A

A

A

Fixed drive - at a 120% Safety Factor of HP A

A

A

A

A

A

A

A

A

A

A

A

A

Fixed drive - selected at a 150% SF of HP A

A

A

A

A

A

A

A

A

A

A

A

A

Adjustable drive - selected at a 120% SF of HP

A

A

A

A

A

A

A

A

A

A

Adjustable drive - selected at a 150% SF of HP

A

A

A

A

A

A

A

A

A

A

Motor starter at 460/3/60, 120 volt holding coil

A

A

A

A

A

A

A

A

A

A

A

A

A

Motor starter at 230/3/60, 120 volt holding coil

A

A

A

A

A

A

A

A

A

A

A

Motor starter at 200-208/3/60, 120 volt holding coil

A

A

A

A

A

A

A

A

A

A

Advertising