Specifications controls/display layout – Honeywell cm921 User Manual

Page 2

Advertising
background image

CM921 CHRONOTHERM

2
EN0H 8557 UK07 R0 09/06



SPECIFICATIONS

CONTROLS/DISPLAY LAYOUT

ELECTRICAL

Room unit power
supply

: 2 x 1.5 V IEC LR6 (AA) Alkaline cells

Battery life

: Minimum 2 years

Battery
replacement

: Program retained in EEPROM

Receiver power
supply

: 230V AC +10% - 15%, 50Hz

Switch type

: SPDT potential free

Output rating

: 24-230 V AC, 10 A resistive, 3 A inductive

0.6 p.f.

Wiring (receiver
only)

: Cable terminals for mains and relay wiring

for max 2.5 mm

2

wire

Wire access

: from the rear (wall box mounting), right

and bottom

RF

RF operation band

: ISM (868.0-868.6) MHz, 1% duty cycle

RF communication
range

: 30 m in a residential building environment

RF communication
technology

: short, high rate transmissions to minimise

air time and avoid collisions

Blocking immunity

: Receiver class 2 (ETSI EN300 220-1

version 1.3.1)

RF binding method

: Factory pre-bound with the room unit.

ENVIRONMENTAL & STANDARDS

Operating
temperature

: 0 to 40

o

C when relay load < 8 A

: 0 to 30

o

C when relay load > 8 A

Shipping & storage
temperature

: -20 to 55

o

C

Humidity

: Humidity range 10 to 90% rh, non-

condensing

IP class

: 30

Meeting the
following
standards

: EN60730-1(Nov 2000), EN55014-1(1997),

EN55014-2(2000), ETSI EN300 220-3
(2000), ETSI EN301 489-3(2000)

TEMPERATURE CONTROL

Sensing element

: 100K (@ 25

o

C ) NTC thermistor

Control form

: Fuzzy Logic Algorithm

Minimum ON
time

10% of cycle time (min one minute),
adjustable to 2 to 5 min (see installer set
up)

Cycle rate

: Selectable by application (see installer

set up)

Temperature
control accuracy

:

+

0.5 K (nominal) @ 20

o

C, 50% load 3K

Δ/hour

Fail-safe mode

: Off or cycling depending on the CM927

system set-up

TIME SETTING/PROGRAMMING

Time display

: 24 hour or 12 hour AM/PM format

Time keeping
accuracy

: Typically better than 10 minutes per year

Program

: 1-day with 6 daily time and temperature

level changes

Time setting
resolution

: Time of day - 1 minute

Program – 10 minute steps

Temperature
setting range

: Program : 5 to 35

o

C in 0.5

o

C steps Frost

: 5

o

C or equal to lower limit (5

o

C to 16

o

C). Frost protection does not

work in cooling mode

Room
Temperature
display range

: From 0

o

C to 50

o

C

Room Unit Layout:

1.

Day & Date Display

2. Time

Display

3.

Dynamic Text Display
(DTD)

4.

Burner On Indicator

5.

Battery Low Indicator

6. Temperature

Display

7. Temperature

Change

Buttons

8. Information

Enquiry

Button

9. Slider

Switch

10.

Green OK Button

11. Program

Buttons

12. Battery

Cover

13. Battery

Compartment

14. Holiday

Button

15.

Time Change Buttons