Repair

44

309293J

Fluid Packing Removal

1.

Prepare the gun for service, page 41.

2.

Remove the air cap and fluid nozzle, page 42.

3.

Remove the electrode, page 43.

4.

Loosen the trigger screws (8) and trigger (30). See
F

IG

. 26..

5.

Remove the packing rod (26), using the multi-tool
(37).

6.

Check all parts for wear or damage and replace if
necessary.

Fig. 26. Fluid Packing Removal

CAUTION

Clean all parts in non-conductive solvent compatible
with the fluid being used, such as xylol or mineral
spirits. Use of conductive solvents can cause the gun
to malfunction.

TI1683A

37

30

8