Caution, Barrel removal, Barrel installation – HP GRACO OR PRO TI1681A User Manual

Page 46

Advertising
background image

Repair

46

309293J

Barrel Removal

1.

Prepare the gun for service, page 41.

2.

Remove the air inlet fitting (35) and take the bracket
(104) off the gun handle (17).

3.

Loosen the three screws (11).

4.

Hold the gun handle (17) with one hand and pull the
barrel (16) straight off the handle. See F

IG

. 28..

Barrel Installation

1.

Be sure the gasket (10*) and grounding spring (55)
are in place. Make sure the gasket air holes are
aligned properly. Replace if damaged. See F

IG

. 29..

2.

Place the barrel (16) over the power supply (18) and
onto the gun handle (17).

3.

Tighten the three screws (11) oppositely and evenly
(about a half turn past snug).

4.

Position the bracket (104) on the gun handle (17)
and secure with the air inlet fitting (35).

5.

Apply dielectric grease (40) to the exposed inner
tube of the fluid hose (101).

6.

Check that the nut (105) is tight on the ferrule hous-
ing (103).

7.

Test gun resistance, page 30.

Fig. 28. Barrel Removal

Fig. 29. Barrel Installation

CAUTION

To avoid damaging the power supply (18), pull the
gun barrel straight away from the gun handle. If nec-
essary, gently move the gun barrel from side to side
to free it from the gun handle.

CAUTION

Do not over-tighten the screws (11).

TI1691A

TI1690A

11

35

104

16

17

17

TI1692A

16

*10

11

18

55

101

104

105

35

Advertising