Draining moisture from the tank, Air filter maintenance, Troubleshooting – Harbor Freight Tools Central Pneumatic Oilless Air Compressor 69666 User Manual

Page 12: Safety opera tion maintenance setup

Advertising
background image

Page 12

For technical questions, please call 1-800-444-3353.

Item 69666

69669

Draining Moisture from the Tank

The Drain Valve is located under the Tank. It must be used daily to release all trapped air and

moisture from the Tank. This will eliminate condensation which can cause tank corrosion.

CAUTION! Do not open the Drain Valve so that more than four threads are showing.

1. Turn the Power switch of the compressor off.

2. Place a collection pan under the Drain Valve.

3. Unthread the Drain Valve two or three turns ONLY.

4. When all the pressure and moisture is released,

close the Drain Valve.

Air Filter Maintenance

Check the Air Filter weekly to see if it needs replacement.

If working in dirty environments, you may need to replace the filter more often.

1. Remove the Cover.

2. Remove the Air Filter.

3. Replace with a new Air Filter.

4. Replace the Cover.

Troubleshooting

Problem

Possible Causes

Likely Solutions

Compressor does

not start or restart

1. Tank(s) already pressurized.
2. Power cord not plugged in properly.
3. Incorrect power supply.
4. No power at outlet.

5. Thermal overload switch tripped.

6. Building power supply circuit tripped or

blown fuse.

7. Cord wire size is too small or cord is too

long to properly power compressor.

8. Compressor needs service.

1. No problem. Compressor will start when needed.
2. Check that cord is plugged in securely.
3. Check that circuit matches compressor requirements.
4. Reset circuit breaker, or have outlet

serviced by a qualified technician.

5. Turn off Compressor and wait for it to cool down.

Resume operation.

6. Reset circuit or replace fuse. Check for low voltage

conditions. It may be necessary to disconnect

other electrical appliances from the circuit or

move the compressor to its own circuit.

7. Use larger diameter or shorter extension cord or

eliminate extension cord. See Recommended Wire

Gauge for Extension Cords in Safety section.

8. Have unit inspected by a qualified technician.

Compressor builds

pressure too slowly

1. Incorrect power supply.
2. Working environment too cold.

3. Safety valve leaking.

4. Loose fittings.

1. Check that circuit matches compressor requirements.
2. Move compressor to a warmer location.
3. Listen for air leaking from valve.

If leaking, replace with identical valve with same rating.

DO NOT SEAL OR TAMPER WITH SAFETY VALVE.

4. Reduce air pressure, then check all fittings with

a soap solution for air leaks and tighten as needed.

Do not overtighten.

Compressor not

building enough

air pressure

1. Air filters need cleaning/replacing.

2. Check Valve needs service.
3. Compressor not large enough for job.

4. Loose fittings.

5. Hose or hose connections too narrow.
6. High altitude reducing air output.

1. Check inlet and outlet filters.

Clean and/or replace as needed.

2. Have technician clean or replace, as needed.
3. Check if accessory CFM is met by Compressor.

If Compressor cannot supply enough air flow (CFM),

you need a larger Compressor.

4. Reduce air pressure, then check all fittings with

a soap solution for air leaks and tighten as needed.

Do not overtighten.

5. Replace with wider hose and/or hose connections.
6. Higher altitudes require compressors with greater output.

Follow all safety precautions whenever diagnosing or servicing the compressor.

Disconnect power supply before service.

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Advertising