Grounding

TO PREVENT ELECTRIC SHOCK AND DEATH

FROM INCORRECT GROUNDING WIRE CONNECTION:

Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded.

Do not modify the power cord plug provided with the compressor.

Never remove the grounding prong from the plug. Do not use the compressor if the power cord or plug is

damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a

proper outlet installed by a qualified electrician.

110-120 V~ Grounded Compressors: Compressors with Three Prong Plugs

1. In the event of a malfunction or breakdown,

grounding provides a path of least resistance for

electric current to reduce the risk of electric shock.

This compressor is equipped with an electric

cord having an equipment-grounding conductor

and a grounding plug. The plug must be

plugged into a matching outlet that is properly

installed and grounded in accordance

with all local codes and ordinances.

2. Do not modify the plug provided –

if it will not fit the outlet, have the proper

outlet installed by a qualified electrician.

3. Improper connection of the equipment-grounding

conductor can result in a risk of electric shock.

The conductor with insulation having an outer

surface that is green with or without yellow

stripes is the equipment-grounding conductor.

If repair or replacement of the electric cord or

plug is necessary, do not connect the equipment-

grounding conductor to a live terminal.

4. Check with a qualified electrician or service

personnel if the grounding instructions are

not completely understood, or if in doubt as to

whether the compressor is properly grounded.

5. Use only 3-wire extension cords that have

3-prong grounding plugs and 3-pole receptacles

that accept the compressor’s plug.

6. Repair or replace damaged or worn cord immediately.

125 V~ 3-Prong Plug and Outlet

(for up to 125 V~ and up to 15 A)

Grounding

Pin

7. This compressor is intended for use on a

circuit that has an outlet that looks like the

one illustrated above in

125 V~ 3-Prong Plug

and Outlet. The compressor has a grounding

plug that looks like the plug illustrated above

in

125 V~ 3-Prong Plug and Outlet.

8. The outlet must be properly installed and grounded

in accordance with all codes and ordinances.

9. Do not use an adapter to connect this

compressor to a different outlet.

Symbology

PSI

Pounds per square inch of pressure

CFM

Cubic Feet per Minute flow

SCFM

Cubic Feet per Minute flow

at standard conditions

NPT

National pipe thread, tapered

NPS

National pipe thread, straight

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes