Troubleshooting (cont.)

Problem

Possible Causes

Likely Solutions

Overheating

1. Air filters need cleaning/replacing.

2. Unusually dusty environment.

3. Extension cord used.
4. Unit not on level surface.

1. Check inlet and outlet filters.

Clean and/or replace as needed.

2. Clean and/or replace filters more often or

move unit to cleaner environment.

3. Eliminate extension cord.
4. Reposition unit on a level surface.

Compressor

starts and stops

excessively

1. Loose fittings.

2. Compressor not large enough for job.

1. Reduce air pressure, then check all fittings with a soap

solution for air leaks and tighten as needed.

Do not overtighten.

2. Check if accessory CFM is met by Compressor.

If Compressor doesn’t reach accessory

CFM, you need a larger Compressor.

Excessive noise

1. Loose or damaged belt guard.
2. Loose fittings.

3. Unit not on level surface.

1. Replace belt guard.
2. Reduce air pressure, then check all fittings with a soap

solution for air leaks and tighten as needed.

Do not overtighten.

3. Reposition unit on a level surface.

Moisture in

discharge air

Too much moisture in air.

Install inline air filter/dryer, and/or relocate

to less humid environment.

Safety Valve “pops” Safety valve needs service.

Pull on test ring of safety valve. If it still pops, replace.

Air leaks from

pump or fittings

Loose fittings.

Reduce air pressure, then check all fittings with a soap

solution for air leaks and tighten as needed.

Do not overtighten.

Air leaks from tank

Defective or rusted tank.

Have tank replaced by a qualified technician.

Drain moisture from tank daily to prevent future corrosion.

Follow all safety precautions whenever diagnosing or servicing the compressor.

Disconnect power supply before service.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM

IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR

MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS

QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE

ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY

STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND

LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY

ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS

THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Advertising