Hand Held Products 5620 User Manual

Page 65

Advertising
background image

IMAGETEAM™ 2020/5620 System Manual

3 - 11

62

code identifier for Code 39

9999 code length that must match for Code 39, 9999 = all lengths
41

start character match for Code 39, 41h = “A”

FF

termination string for first code

6A

code identifier for Code 128

9999 code length that must match for Code 128, 9999 = all lengths
42

start character match for Code 128, 42h = “B”

FF

termination string for second code

69

code identifier for Code 93

9999 code length that must match for Code 93, 9999 = all lengths
43

start character match for Code 93, 43h = “C”

FF

termination string for third code

To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on

page 3-10

, but assume a <CR> suffix and

specific code lengths, you would use the following command line:

SEQBLK62001241FF6A001342FF69001243FF

The breakdown of the command line is shown below:

SEQBLK sequence editor start command
62

code identifier for Code 39

0012

A - Code 39 sample length (11) plus CR suffix (1) = 12

41

start character match for Code 39, 41h = “A”

FF

termination string for first code

6A

code identifier for Code 128

0013

B - Code 128 sample length (12) plus CR suffix (1) = 13

42

start character match for Code 128, 42h = “B”

FF

termination string for second code

69

code identifier for Code 93

0012

C - Code 93 sample length (11) plus CR suffix (1) = 12

43

start character match for Code 93, 43h = “C”

FF

termination string for third code

Advertising