Data editing, Prefix/suffix overview, Chapter 4 - data editing – Hand Held Products 5620 User Manual

Page 67: Prefix/suffix overview -1

Advertising
background image

IMAGETEAM™ 2020/5620 System Manual

4 - 1

4

Data Editing

Prefix/Suffix Overview

When a bar code is scanned, additional information is sent to the host computer
along with the bar code data. This group of bar code data and additional,
user-defined data is called a “message string.” The selections in this section are
used to build the user-defined data into the message string.

Prefix and Suffix characters are data characters that can be sent before and after
scanned data. You can specify if they should be sent with all symbologies, or
only with specific symbologies. The following illustration shows the breakdown
of a message string:

Points to Keep In Mind

It is not necessary to build a message string. The selections in this chapter
are only used if you wish to alter the default settings.

Default prefix = None.

Default suffix = None.

A prefix or suffix may be added or cleared from one symbology or all
symbologies.

You can add any prefix or suffix from the

ASCII Conversion Chart (Code Page

1252)

on page A-2, plus Code I.D. and AIM I.D.

You can string together several entries for several symbologies at one time.

Enter prefixes and suffixes in the order in which you want them to appear on
the output.

When setting up for specific symbologies (as opposed to all symbologies), the
specific symbology ID value counts as an added prefix or suffix character.

Prefix

Scanned Data

Suffix

1-11
alpha numeric
characters

variable length

1-11
alpha numeric
characters