Test and adjustment, Specifications – Heath Zenith SL-5326 User Manual

Page 3

Advertising
background image

3

598-1269-00

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Motion

Motion

The detector is most sensitive to motion across its field
of view.

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 1" (2.5 cm) away from
the lamps.

Adjust the RANGE as needed.

RANGE set too high may
increase false triggering.

Secure the sensor head by
tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 20 minutes).

Set the D

ual

B

rite

®

switch to the amount of time

after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost. [varies
with surrounding temperature]

Sensing Angle . . . . . . Up to 240°
Electrical Load . . . . . . Up to 300 Watt Maximum In-

candescent [Up to 150 Watt
maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 20 minutes
D

ual

B

rite

®

Timer . . . . 3, 6 hours, Dusk-to-Dawn

DESA Specialty Products

reserves the right to dis-

continue products and to change specifications at any
time without incurring any obligation to incorporate
new features in products previously sold.

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

70 ft.

(21 m)

8 ft.

(2.4 m)

240°

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Least Sensitive

Most Sensitive

Sensor

Warning - Risk of fire. Do not aim the lamps

at a combustible surface within 3 ft. (1 m).

Maximum Range

Maximum

Coverage Angle

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME DUAL BRITE

TEST 1 5 2 0

MINUTES

OFF 3 6 DUSK TO

HOUR DAWN

100 ft.

(30.5 m)
Boosted

Turn the RANGE control to the mid position,

D

ual

B

rite

®

to OFF and the ON-TIME control to the

TEST position.

Advertising