1. Factory Default Settings:

a) Temperature Settings: Refrigerator: 36°F (2°C); Freezer: -4°F (-20°C).
b) Temperature Display Scale: °F.

For further details, see "II.C. Control Module Check" or "III. Controls and Adjustments."

Note • When exposed to high temperatures, a high-temperature alarm "Hi" may occur

at startup. To silence the alarm, press and release the upper button. Alarm
automatically resets when temperature drops to an acceptable range.

• There is a minimum 2-min. Comp on time and 2-min. Comp off time.

1) Move the power switch to the "OFF" position.
2) Unplug the appliance from the electrical outlet.
3) Remove the control box cover.
4) Plug the appliance back into the electrical outlet.
5) Move the power switch to the "ON" position.
6) Confirm 115VAC at the power switch. On 3-section models, also confirm proper supply

voltage at the receptacle box (115VAC for refrigerator/208-230VAC for freezer).
Continue to the appropriate section:
"II.B.1a. Refrigerator-Control Module with Remote Display Module"
"II.B.1b. Refrigerator-Control Module with Integrated Display"
"II.B.2a. Freezer-Control Module with Remote Display Module"
"II.B.2b. Freezer-Control Module with Integrated Display"