Installing vent pipe and appliance, Caution – Heatiator ADI60S User Manual

Page 11

Advertising
background image

11

Heatilator • ADI60S • 345-900 Rev. G • 9/08

A. Venting Components

7

7

Installing Vent Pipe and Appliance

The vertical vent termination system installed on this model
includes:

• One length of 3-inch fl exible vent pipe for combustion

air (included with vent kit). Pipe will be either a 4-foot
or 30-foot section depending on which kit is being used
in the application.

• Flexible vent pipe for exhaust air (included with vent kit).

• One pipe-to-cap adaptor (included with vent kit).

• One vertical termination cap (included with vent kit).

EXHAUST

AIR

VENT PIPE

TERMINATION

CAP

EXHAUST STARTING COLLAR

STARTING COLLAR BRACKET

EXHAUST STARTING COLLAR

INLET AIR STARTING COLLAR

STARTING COLLAR BRACKET

INLET AIR STARTING COLLAR

LOCKING TAB

INLET AIR
VENT PIPE

Figure 7.1

B. Connecting Vent Pipe

Reference instructions in the termination kit.

• Install the 3-inch fl exible vent pipe(s) down through the

chimney.

• Use three screws to secure the exhaust fl exible vent

pipe to the 3 foot section stainless steel fl exible vent pipe
using the factory-installed 3-inch collar in the stainless
steel section of pipe (see Figure 7.1).

• Use 3 screws to attach either a 4 foot or 30 foot section

of inlet air vent to the inlet collar on the collar slide plate
(see Figure 7.1). NOTE: The collar slide plate may be
removed from appliance to aid installation.

• Seal opening between fl ex vent and chimney just above

insert. Non-combustible, unfaced fi berglass insulation
may be used for this purpose.

CAUTION

Sharp Edges
• Wear protective gloves and safety

glasses during installation.

Advertising