Warning, G. glass assembly h. air shutter setting – Heatiator ADI60S User Manual

Page 25

Advertising
background image

25

Heatilator • ADI60S • 345-900 Rev. G • 9/08

Figure 11.5 Glass Assembly

G. Glass Assembly

H. Air Shutter Setting

Optimal fl ame appearance is dependent on the air shutter
setting. Adjustments should be made by a qualified
technician.

Handle glass doors with care.

• Inspect the gasket to ensure it is undamaged.

• Inspect the glass for cracks, chips or scratches.

• Do NOT strike, slam or scratch glass.

• Do NOT operate appliance with glass door removed,

cracked, broken or scratched.

• Replace glass door assembly as a complete appliance.

WARNING

Model

NG

LP

Burner

ADI60S

3/8 in.

Full Open (3/4 in.)

BOTTOM LATCH

GLASS ASSEMBLY

Removing Glass Assembly

ADI60S

To release glass assembly, pull the two bottom spring-

loaded latches forward and allow them to retract away from
the glass assembly. Remove glass assembly by carefully
pulling the bottom side of the glass assembly out fi rst.
Carefully slide the glass assembly outward and downward
until the top tabs are disengaged from the slots.

Replacing Glass Assembly

ADI60S

Tilt glass assembly toward fireplace and slide glass

assembly up to engage top two tabs with the corresponding
slots. Fasten the two bottom latches.